Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

Status Completed
Product PI Connectors
Categories PI System Connector
Created by Guest
Created on Aug 20, 2022

PI System Connector Destination AF Configuration String should not Contain Source PI Server Name if it is Unreachable

Currently, if the PI Server specified in the source PI AF server is unreadable from the PI System Connector node, the Connector will forward the listed source PI Server name in the configuration string to the destination AF Server. This causes confusion as the Destination AF server will likely not have access to the unreachable source PI Server. Instead, The connector should create a configuration string on the destination AF server stating that the source PI Server Host is unreachable.
  • ADMIN RESPONSE
    Aug 20, 2022
    Functionality of the connector was updated in version 2.3.1.1 so that when the source PI AF database is configured with a Default Data Server, the destination PI AF database no longer updates the destination PI AF database’s Default Data Server.
  • Attach files