To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Search results

Showing 3183 of 3183

Allow PI-ICU to Create/Edit Stored Credentials in Credential Manager

An issue we run into often is that most of the accounts that are used to run our interfaces (mostly OPC DA) are different from accounts we use to configure the interfaces. Because these interfaces run on different domains, we have to store an acco...
Brian Rock over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 4 No status

Support Automatic Failover for PI UFL

Currently UFL only supports two independent instances for redundancy purposes.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 Declined

PI OPCtoCSV Tool: Subbranch filter depth

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. It is possible to filter the items by subbranch however it recurses all sub-subbranches. We have an OPC server with around 20k items that we read into ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI interface for OPC .. UA

it would be useful to have an interface that can connect and retrieve data from OPC UA server. it will help to avoid using any additional software for "downgrading" the protocol to OPC at client side.
ValterFostini over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Uni-Int to write to scan-class health tags on startup

We've noticed this particularly with the RDBMS-PI interface when configured for failover: Health tags that are only written to when the interface becomes primary or has completed its first scan (eg Point Count, Scan Class I/O Rate etc.) say 'Intf ...
Guest over 3 years ago in PI Interfaces / General 0 No status

Separate commonly used PI Interfaces that do not have a successor into read-only and write-only versions

Currently, it is recommended to use the read-only version of a PI Interface if only reading is required, and to have separate read and write instances of the read-write version of a PI Interface if writing is required. (Reference: https://docs.osi...
Kenneth Barber over 3 years ago in PI Interfaces / General 1 No status

Allow using SQL as a data source for FactoryTalk Batch

Rockwell FactoryTalk Batch v12.01 allows to output batch data to a SQL database as well as EVT files. Just like with EMDVB, the PI Interface for FTBatch should be able to use both data sources.
Alan Izar over 3 years ago in PI Interfaces / Batch Interfaces 1 Declined

Connector for GE HABConnect

Having a connector available for GE HABConnect rather than the interface would be useful to customers that are dealing with large amounts of data and make frequent changes to points on the GE side.  A connector that is capable of automaticall...
Guest over 3 years ago in PI Connectors / New PI Connector Request 0 No status

PI Connector for Mitsubishi Electric MELSEC

Develop a connector for Mitsubishi Electric MELSEC
Guest over 3 years ago in PI Connectors / New PI Connector Request 1 No status

PI Connector for AMQP

Develop a connector for AMQP
Guest over 3 years ago in PI Connectors / New PI Connector Request 0 No status