Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results

Showing 237 of 3183

PI Event Frames Interface Manager

Hello, the PI Event Frames Interface Manager application must be run in the same machine that hosts the PIEFGen interface. This is an issue regarding our security rules because, the PIEFgen interface runs in secured machines and we don't want to a...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 2 Declined

Enhance how batch interfaces write to the message logs

Batch interfaces should write their messages to the message logs using the Source1 and Source2 fields just like UniInt based interfaces. Currently, batch interfaces leave these 2 fields blank. Source1 should contain the process name or similar and...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

BACNet: Add support for Conversion Factor PI Point attribute to PI Interface for BACNet

Add support for Conversion Factor PI Point attribute to PI Interface for BACNet. Note: This was previously Enhancement 118928.
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Fix PI XMLTool (bundled with PI Interface for OPC XML-DA)

The PI XMLTool that is bundled with the PI Interface for OPC XML-DA does not function with Windows Server 2019 even though the PI Interface for OPC XML-DA itself is documented to function. Can the client tool please be worked on so that it will fu...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Create 'Close Event Frame delay' setting

When you create PI Point Data Reference attributes in event frame templates that are used by PI Batch Interfaces, the PI Batch Interface will be responsible for resolving and capturing this PI Point data as soon as it closes the corresponding even...
Rafael Batista 10 months ago in PI Interfaces / Batch Interfaces 0 No status

Enhance AutoPoint Sync APS to sychronize point sets larger than 100,000 points

https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01426 PI AutoPoint Sync is a 32-bit application an can only synchronize 100,000 points in a point source. Recommend to develop the application to use a 64-bit architecture to h...
Luke Peters over 3 years ago in PI Interfaces / Other Interfaces 0 No status

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

Define more explicit system requirements for PI Interfaces

Define more explicit system requirements for PI Interfaces. According to a customer, despite the Buffer and Bandwidth Calculation Spreadsheet, currently available information does not allow for accurate hardware sizing.
Guest over 3 years ago in PI Interfaces / Installation 0 No status

PI ICU should not allow PItoPI COLD failover configuration

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, the PI Interface configuration utility still allows COLD failover to be selected....
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

PI UFL Interface can read input files from non-UNC paths such as Azure File share

I would like the PI UFL Interface to be able to directly read from input files that are in non-UNC paths such as Azure File share, so I do not need to periodically copy the input files into another path.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status