To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results

Showing 301 of 3183

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status

Store bad quality from OPC server

Enhance the OPC DA Interface to store bad quality values from his OPC Server in PI, so that the values, timestamp and status from bad quality data are saved in PI.  Note: This was previously Enhancement 114636.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 2 No status

Extend PI Data Archive time zone setting support

Currently PI DataLink allows you to select the PI Data Archive time zone setting however this setting only applies to data items or expressions that contain either a PI point or a PI AF attribute that is a PI point data reference. If the data item...
Guest 6 months ago in AVEVA™ PI DataLink™ / Settings 0 No status

Update EFGen Interface Health Tags To Allow For Better Status Monitoring

The current EFGen interface "Status" health tag displays a value of "Good" if it is connected to the data source but does not factor in if it is writing Event Frame data to PI. There is not currently a straightforward way to drive a PI Notificatio...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 2 No status

Avoid necessary registry correction after Click To Run Office update

At our company the unit responsible for deploying software knows about the article KB01529 (Errors with PI DataLink when updating or upgrading Click To Run Office). But they state: According to OSIsofts problem with PI and Office 365 click to run...
Guest about 3 years ago in AVEVA™ PI DataLink™ / Installation & Upgrading 3 Completed

OPC interface retries sending InstrumentTag/ItemID to OPC Server

The idea is to have PI Interface for OPC DA/HDA to be able to send again Instrument Tag/Item ID after a configurable time when OPC Server is not able to resolve it (AddItem failed). This would be a workaround for an OPC server issue and would help...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 3 No status

File name extensions "_OK" and "BAD" / Deletion of correctly read lines

We operate a UFL interface that evaluates CSV files with additional analysis data and reads data for existing PI tags, storing the values (including timestamps) in the PI server archives. Our UFL interface is not permitted to create PI tags. I hav...
Werner Geller about 1 month ago in PI Interfaces / PI Interface for UFL 0 No status

Add SOAP 1.2 support to the PI Interface for OPC XML-DA

The current version of the PI Interface for OPC XML-DA seems to only support SOAP 1.1. All recent OPC XML-DA servers are developed following SOAP 1.2 standards, meaning the PI interface will not connect. Please enhance the interface to also suppor...
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

configure the PI DataLink language independently of the Microsoft Office language setting.

"Beginning with PI DataLink 2022 it uses the Office language to display the localized functions." Because the customer’s organization operates globally, individual users may have different Office language settings. To maintain consistency, they wo...
Runpu YAN about 2 months ago in AVEVA™ PI DataLink™ / Format 0 No status

Modify the Modbus Interface to accept 32-bit Unsigned Ints from the PLC

provide a data type to accept a 4 byte unsigned integer from the PLC.  At this point, it would be stored in a 64-bit float in PI DA.
Clint Ramsey over 3 years ago in PI Interfaces / PI Interfaces for Modbus 3 Declined