Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results: AVEVA™ PI Server

Showing 97 of 330

Powershell PIArchive.Reprocess

A powershell method for reprocessing PI Archve Files. $myPIArchive = Get-PIArchiveFileInfo -Connection $myPi -Name "someArchiveFile" $myPIArchive.ReprocessArchive -NewFileName $false|"filename" -Type Dynamic|Fixed -OtherCoolOptions Reading data...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 Completed

PI Analysis: Auto-backfill should not skip analyses - ones that hasn't had an new value in a while (72+hrs)

Whenever the PI Analysis Service is restarted, the auto-backfill feature (if enabled) kicks in, and backfills any gaps from the downtime. However, the analysis service will not auto-backfill analyses that haven't been updated in the last 72 hours...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 9 Completed

Edit Notify Option in bulk

They want to know if it is possible to set the Subscriber Notify Option as Event start and End as default in the new PI Notifications Rules They claim it is hard to set it for all the subscribers one by one. There is currently no way to do that ...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 3 Completed

Configurable default Attribute ConfigString

Right now, when you create an attribute in a template and assign it a Data Reference of PI Point, it defaults to a ConfigString of "\\%Server%\%Attribute%". %Server% has some known administrative headaches because what it populates as is dependent...
taterhead247 over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 Completed

Have pre-made PI Identities with minimum permissions by default

It currently takes more effort to follow AVEVA's recommendation of setting minimum permissions for all PI service accounts than it is to use fewer service accounts with more permissions. To help steer PI administrators in the right direction, plea...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 2 No status

Improve version control mechanism to consider also PI AF Analysis & Notifications Elements

Improve version control mechanism to consider also PI AF Analysis & Notifications Elements: Background: When adding or removing an attribute to an Element in PI AF, the element's revision number is incremented (as expected) which makes the re...
Moshe Sabag over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Include the "Primary Parent" checkbox functionality under PSE's "Change Reference Type" dialog in PI Builder

In PSE, you can right click an element reference > Convert > Change Reference Type... and have the option to make your current element reference the Primary Parent via a check box. This functionality is not replicated in PI Builder. Thus, yo...
Guest over 3 years ago in AVEVA™ PI Server / PI Builder 0 No status

PI Server is taking a lot of resources to interpolate a value before the first archived value

In a rescent issue we faced, we discoreved that when you try to interpolated a value before the first archived value on a system with a lot of archive files, the system must read all the archive files trying to find a previous value for interpolat...
marc.cote 5 months ago in AVEVA™ PI Server / Data Archive 0 No status

Include Windows Counters/OMF Health for Message Log Event Rate

Having metrics that count the number of messages being written to the message log, and categorized by severity, gives a great dashboard overview of the status of PI data archive. For example, having a events/min count of error messages historized ...
Mike Horrocks over 1 year ago in AVEVA™ PI Server / Data Archive 0 No status

Correct pointDB_RemoveEmptySource behaviour or change Point Source Management

Hello, About the tuning parameter pointDB_RemoveEmptySource the following Article : https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB01008 Indicates : Perform any of the following actions to trigger removal of empty point sou...
Lionel Gergaud almost 2 years ago in AVEVA™ PI Server / Data Archive 2 No status