To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Search results

Showing 3181 of 3181

PI to PI interface should perform first scan so that future data can recovered

/fd parameter is only used while performing real-time scan. If scan rate is set to a higher value such as a day, the user would need to wait for the first scan (after a day) to get future data. This should be done at interface startup. For use cas...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 Declined

Provide data validation tools to verify moving history from one PI Server to another using PI to PI Interface

There is no easy way to verify that historical data moved from one PI Server to another using the PI to PI Interface isn't missing data on the target PI Server.
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

PI UFL Interface - create selected tags using EnablePointCreation parameter.

Customer noticed that tags can be created automatically, but he does not want to create all of the tags autmatically, but select which tags will be created. He wants to be able to select which tags will be created and which won't.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 1 No status

Suppress the message "exception attributes corrected through the SDK read"

In the PI Interface of UFL we would like the option to suppress the message: "exception attributes corrected through the SDK read" for values of excmax larger then 9hrs.
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status

Please allow to use a hex value as a delimiter, which will allow to specify a Carriage Return (0x0D) as a delimiter

While PI Connector for UFL supports FOREACH (CsvGetItem(__Message, char(13))) to allow using a Carriage Return as a delimiter, it does not support Serial input. This leaves PI Interface for UFL the only option to work with Serial input. Please al...
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 1 Declined

Increase max. service ID for PI UFL Interface

According to https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=3645819457236571808-241124 , any number larger than 99 can NOT be specified for PI UFL Service ID. It would be better for us if the larger number such as 300 could b...
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 0 No status

Modifying the functionality of Trend Advise feature for PI OPC interface

As a PI OPC Interface user I would like to get step-like trends whenever that the Trend Advise parameter is enabled (even with having large exception and compression deviations that filter some of the events) so that I don't need to enable the ste...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

debug an arbitrary number of tags belonging to a PI OPC interface instance

It is currently possible to debug one tag, or all tags. Logging timestamp and data for all tags is expensive and make logs harder to read, so one one would like to select an arbitrary number of tags.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 Declined

PI Interface for OPC DA retry writing data when it receives a CONNECT_E_ADVISELIMIT error.

I would like the ability for the PI Interface for OPC DA to retry writing data when it receives a CONNECT_E_ADVISELIMIT error. Certain OPC servers return a CONNECT_E_ADVISELIMIT error when write requests are received in quick succession, and havin...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 Declined

Automatically recreate advise groups when they are discarded by RSLinx OPC Server

The Rockwell RSLinx OPC Server may discard advise groups when there are too many bad quality tags or incorrect ItemIDs added to the group. The PI Interface for OPC DA should automatically recreate advise groups after it has determined that the gro...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status