To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results: PI Interfaces

Showing 52 of 781

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta about 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI Event Frames Interface Manager

Hello, the PI Event Frames Interface Manager application must be run in the same machine that hosts the PIEFGen interface. This is an issue regarding our security rules because, the PIEFgen interface runs in secured machines and we don't want to a...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 2 Declined

Ability to monitor changes in interface configuration.

Need to know when the interface configuration was edited and which parameter was changed.
Mohammed Qasim Asghar about 2 years ago in PI Interfaces / General 0 Declined

RDBMS time stamp precision

Currently the ODBC connection is configured with a SQL date time parameter when retrieving the TS parameter (snapshot time stamp). Due to the fact lots of sources system having more precision in their time stamps, it makes it hard to compair sourc...
meierke1 over 3 years ago in PI Interfaces / PI Interface for RDBMS 0 No status

PI ICU should not allow PItoPI COLD failover configuration

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, the PI Interface configuration utility still allows COLD failover to be selected....
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 No status

Add a configuration option to the OPC DA Interface so that the user can adjust the maximum advise tag exception delay for Event/Trigger tags

This affect to delay in Event\Trigger points. KCS: Delay in Event Points. When using Event Points, we purposefully do have a delay (if excMax is > 2 s then 2 s else 0.9*excMax) for advise tags (Trigger Point) before they're sent to the PI Serv...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Add a configuration option to UniInt so that the user can adjust the minimum wait time for checking for new events from the Update Manager

This affects the delay in Event\Trigger tags. KCS: Delay in Event Points. The largest and most variable delay seems to come from the time the event is written to the PI Server and the time the interface (UniInt) picks, which is between 0ms-1,000m...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Configure PI Interface for Emerson-Ovation to read drop status points Ovation.

knowing in real-time if an ovation server is down and would help with maintaining the PI server.
Betty about 1 year ago in PI Interfaces / Other Interfaces 0 No status

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest over 2 years ago in PI Interfaces / PI to PI Interface 0 No status