Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Search results

Showing 68 of 199

Add a type casting function or operator

The INI files would be shorter and more readable if the PI Connector for UFL had a type casting function or operator. For example, if you are incrementing a Counter variable (type Int32) for each data line, and your tag names are Tag1, Tag2, etc....
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

PI Connector for J1939/CAN

Connectivity to J1939/CAN based data sources; used for connectivity to operational and diagnostics data from commercial vehicles and heavy construction equipment.
Guest over 3 years ago in PI Connectors / New PI Connector Request 1 No status

Allow real-time data flow to continue for connectors when the Point Count Maximum has been exceeded

When the point count maximum defined in the license file has been exceeded, this interrupts real-time data flow for all PI Connectors until the error is cleared. This affects an reports or time-sensitive operations relying on production data. Data...
Guest over 3 years ago in PI Connectors / General 0 No status

Date and time format in Preview-Results pane (PI System Explorer) to be consistent with all other date & time formats

The Date and time format in PI System Explorer's Preview-Results pane are not displayed according to the end user's operating system date & time format defined. This is an inconsistent behavior to that of PI System explorer in general sine the...
Moshe Sabag over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add support to create custom AFAnalysisRule plugins

I would like to create a custom AFAnalysisRule that allows us to leverage the resources on the PI Analysis Service to perform calculations that the Analysis Service currently cannot perform. These calculations include matrix operations, array oper...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Add Continue() Function To Asset Analytics

Similar to the Exit() function, a Continue() function would be very helpful in reducing the calculation load on my analysis service, in this case by not fully executing variables if a condition is true. For example, if I'm evaluating the state of ...
Kelsey Bobeck over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Have Option to Enable Exception Testing

Related enhancement request: https://feedback.osisoft.com/forums/555139/suggestions/37362121. There are use cases where the need for exception go beyond simply reducing network traffic achieved by the current wire-level compression. The Ethernet ...
Guest over 3 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Selectively send source data to PI based on triggering conditions

Example 1: If Circuit Breaker trips, begin sending high frequency load, voltage data, etc. Under normal operations do not send this data. (condition must allow for definition of a moving window, i.e. Trip occurs, data just before the trip must be ...
Guest over 3 years ago in PI Connectors / General 0 Declined

Allow specifying a range of older archive files to backup in piartool

The piartool -backup command has multiple parameters that allow for specifying a number of archives to copy. For example it is possible to specify a number of archives to backup starting at the current time (-numarch), or each archive number can b...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status