To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Search results

Showing 690

Allow to move a tag or an AF attribute from one symbol to another

This feature was existing in PI Coresight. For exemple, Taking a value displayed on a trend, drag and drop it to an other symbol (ie. a table) to change the way it is represented
jerome.boudon over 3 years ago in AVEVA™ PI Vision™ / User Experience 0 Declined

Gauge: Show the min/max/avg values on gauge

PI Coresight 2016 does not show the min/max/avg data value on a gauge the way that previous versions of PI Coresight did.
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 Declined

Support for D3 Symbols

Support for Symbols by D3 within PI Vision. https://d3js.org/
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 Declined

Graphische Darstellung importieren (Import graphic representation)

Kann man graphische Darstellungen aus OSI direkt nach PI Vision übernehmen (z.B. Reaktoren)?
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 Declined

PI Vision table to report secondary value when primary hits threshold

Ability for a table to report another value when the primary value on the table hits a threshold. I.e. Voltage will be reported when the max amperage is reached on that PI Vision display.
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 Declined

Allow connectors to write to a buffered PI Point

The customer stores shelving and alarming event data in the same PI point, as they are two parts of a full picture. They receive alarm data through the interface for OPCAE, however shelving events are not exposed through this data path, and they h...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 Declined

DNP3 Interface specify Class for scans

Create some way to configure PI Points belonging to a DNP3 interface instance such that the interface only requests data for a single class (Class 1/Class 2/Class 3) and not all three? Essentially, an event scan that will request one specified Cla...
Guest over 3 years ago in PI Interfaces / PI Interface for DNP3 0 Declined

PI to PI interface should perform first scan so that future data can recovered

/fd parameter is only used while performing real-time scan. If scan rate is set to a higher value such as a day, the user would need to wait for the first scan (after a day) to get future data. This should be done at interface startup. For use cas...
Guest over 3 years ago in PI Interfaces / PI to PI Interface 0 Declined

Please allow to use a hex value as a delimiter, which will allow to specify a Carriage Return (0x0D) as a delimiter

While PI Connector for UFL supports FOREACH (CsvGetItem(__Message, char(13))) to allow using a Carriage Return as a delimiter, it does not support Serial input. This leaves PI Interface for UFL the only option to work with Serial input. Please al...
Guest over 3 years ago in PI Interfaces / PI Interface for UFL 1 Declined

debug an arbitrary number of tags belonging to a PI OPC interface instance

It is currently possible to debug one tag, or all tags. Logging timestamp and data for all tags is expensive and make logs harder to read, so one one would like to select an arbitrary number of tags.
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 Declined