Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 46 of 5213

Automatic sending of historical data (backfill) after communication

Be able to backfill data for a significant amount of time if there is a undetected or temporary uncorrectable network failure.
Guest over 3 years ago in PI Cloud Connect 1 No status

Extend the history recovery max period for PI Cloud Connect to longer than 30 days

Allow history recovery for PI Cloud Connect to be longer than the current max of 30 days
Guest over 3 years ago in PI Cloud Connect 1 No status

PI Cloud Connect should be able to write to more than one Data Archive

I am a subscriber who receives data from multiple organizations in different (>15) subscriptions. Due to needing the data to be located in different Data Archives as each is for a different business area, one instance of PI Cloud Connect should...
Guest over 3 years ago in PI Cloud Connect 0 No status

Migration from interface to connector

Would like a way to migrate from interface to connector as easily as possible.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 2 No status

Add failover capability for the BACnet Connector.

Failover similar to the UFO available for UNIint interfaces.  Warm failover would be sufficient, although I'm sure there are some who would like cold and hot as well.
Chris Wozniak over 3 years ago in PI Connectors / PI Connector for BACnet 1 No status

Allow administrators to remove systems from the PI Cloud Connect portal that are no longer in use

As an administrator, if I were to move my PI Cloud Connect nodes to new machines, I would like the ability to clean up my tenant portal by removing old system names that are still present.
Guest over 3 years ago in PI Cloud Connect 0 No status

Cannot use Office365 account to enable my PI Cloud Connect account

I cannot use my Office365 account to activate my PI Cloud Connect account, because it is a compliance issue in my company to use any other account but the Office365 account to activate this.
Guest over 3 years ago in PI Cloud Connect 0 No status

Send automatic e-mail notification about error status of data transfer

Problems as: - PI Cloud Connect node cannot connect to PI Data Archive, - Account/Password has been expired (service not running properly), - Publications not sending data, and so on. Would be reported to administrators automaticky.
Guest over 3 years ago in PI Cloud Connect 1 No status

BACnet SC/SuperConnect Support

Support for the BACnet SC/SuperConnect protocol for the PI Adapter, PI Connector, or PI Interface.
Connor Hawkins almost 2 years ago in PI Connectors / PI Connector for BACnet 4 No status

trend log objects (BACnet object type 20) available from the connector

BACnet trendlog object present the opportunity to buffer at the edge where the data is collected and to gracefully recover from comms outages if data collection has been impacted. I would suspect the trendlog object could be handled similarly to ...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status