To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 424

OPC UA server failover based on watchdog tag

Gen2 PI Connector for OPC UA support OPC UA server level failover. How the Connector determine when to failover to the other OPC UA server: As per 6.6.2.4.2 ServiceLevel , this is used by the client to determine whether to connect/disconnect fro...
Ee Sheing Lee 18 days ago in PI Connectors / PI Connector for OPC UA 1 No status
137 VOTE

Referencing attributes on other Elements for PI Notifications 2016 Message

Request : Being able to show Attribute values from other Elements other than the attributes on the Referenced Element for the Message in Notification 2016. Description : From the old version, it was possible for a notification message to display ...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 9 No status
118 VOTE

PI OPC UA Connector Array support

Add reading capability for OPC UA Arrays. Currently items with “ValueRank“ = 1 are ignored.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 11 No status
111 VOTE

List all Notifications and its subscribers

Managing thousands of notifications can be difficult. There should be an option to export all the notifications and its subscribers. In PI Builder, you can find information about notifications via Contacts and Elements. There should be a direct wa...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 10 No status
108 VOTE

Support HTTP Token Authentication to a REST Endpoint

The REST endpoint from which I want to pull data requires token authentication. I would like the UFL Connector to be able to obtain the token given the username and password I enter on the Admin page.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 6 No status

It would be great to have an option to backfill/recalculate Event Frame analysis without sending notificaiton.

I know, that notifications are not sent for event frames older than 72 hours, but that 3 days is still too long. Usually we just want to recalculate  Event Frames to have a proper statistic about the past in reports. The notification is use...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 10 No status

PI OPC UA Connector to write Bad Input/Configure

PI OPC UA Connector to write Bad Input/Configure when the respective NodeId is no longer available in OPC UA Server.
Fnu Safdar 16 days ago in PI Connectors / PI Connector for OPC UA 0 No status

Configurable input REST data queue file size for PI Connector for UFL

We're working with a large AMI customer, using the PI Connector for UFL as a REST server endpoint to receive meter data. However, during large interrogations, the amount of messages received can be faster than UFL can process, leading to overflowi...
Kendell Jillson about 1 month ago in PI Connectors / PI Connector for UFL 0 No status

Allow Copy & Paste of Notification Rules

I would like to be able to copy a notification rule in PI System Explorer from an existing element or template and paste it on another element or template. That way when I have similar notification rules, I can copy/paste and make only the changes...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 6 No status

Control which PI/AF servers each data source sends data to.

Right now, for one instance of the connector, all configured data sources will send data to all configured PI Data Archives and PI AF Servers. It is all or nothing. Due to the fact that you cannot have multiple instances of the same connector on a...
Guest over 3 years ago in PI Connectors / General 0 No status