To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 233

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest about 17 hours ago in PI Interfaces / PI Interface for OPC DA 1 No status

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest about 23 hours ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface not truncate the trailing "-#" index (e.g. UnitProcedureName-1) at the end of a Unit Procedure

Some FactoryTalk batch processes have overlapping Unit Procedures with trailing indexes. Because the trailing index is truncated it results in overlapping Unit Procedures with the same name which are then merged. The desired behavior would be for ...
Guest about 23 hours ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface capture "Active Step Change Commencing" events as event frames

Some FactoryTalk batch processes require "Active Step Change Commencing" event to be part of the batch hierarchy however the PI Interface for Factory Talk Batch starts event frames only on [EVENT] = "System Message" or "State Change".
Guest about 23 hours ago in PI Interfaces / Batch Interfaces 0 No status

Subsecond Cropping for Improved Timestamp Handling

The OPCDA interface currently can only handle subsceonds by ignoring them as mentioned in "Ignore Subsecond Timestamps" under PI Interface for OPC DA - Data Handling settings. However there are use cases where users would like to simply limit the ...
Mohammed Shahin 29 days ago in PI Interfaces / PI Interface for OPC DA 0 No status

PI Interface for OPC UA

While it is understood that adapters are the future of data source connectivity; there is an immediate need for existing PI system users (especially in the Chemical industry) to transition their data sources from using OPC DA to OPC UA. Many of th...
Brian Rock over 1 year ago in PI Interfaces / General 0 No status

Remote PI ICU

Regardless of where interface info are stored (PI Module DB or AF), it would be useful to have a remote client tool allowing administrator users to configure interfaces  like they do with tags and AF objects. Today when you have to change con...
MAl over 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 2 No status

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber over 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status

Make PI ICU to support gMSA for Service creation

gMSA are the way of having secured logins for windows services and we try to spread the awareness to switch from standard user accounts to these account type. However as most of the PI applications supports to define the gMSA during installation o...
Ondřej Kafna about 1 month ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

Improve collection of Event Viewer logs in PI Interface for Microsoft Windows Event Log

The PI Interface for Microsoft Windows Event Log can capture Event Viewer Logs. Some of the logs in sub-folders cannot be captured by the interface. This includes logs that store PI information, such as PI Vision with the log: OSIsoft-PIVisualizat...
Ted Birky about 1 month ago in PI Interfaces / Other Interfaces 0 No status