To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 13 of 5194

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Update PI Vision API documentation

As updates are made to the PIVisionAPI, it will be extremely useful to update its documentation.
Laurie Dieffenbach 12 months ago in AVEVA™ PI Vision™ / Help / Documentation / Videos 0 No status

Configurable Help

Make het possible to customize this "Help button" (Help button in PI-Vision) to add links to own (local) websites. Or make a custumizable ribbon like in Microsoft Office.
MauricevB over 3 years ago in AVEVA™ PI Vision™ / Help / Documentation / Videos 2 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Embed more videos inside of help topics

As a user, I would like to see more videos inside of various help topics/articles SO THAT I can get a clear demo that shows me what I'm trying to do.
Guest over 3 years ago in AVEVA™ PI Vision™ / Help / Documentation / Videos 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Release documentation for SVG PB DTD

Maybe this is a ProcessBook issue, but since I'm generating SVG files for inclusion in PI Vision, here goes... I have asked, but looks like documentation for the namespaces of Processbook generated SVG files are not published to the public. ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Help / Documentation / Videos 0 Declined

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Matthew Kishe almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration