To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 481 of 5220
344 VOTE

Connector-level Failover - OPC UA 2.x

Support connector-level failover in PI Connector for OPC UA 2.x (relay-enabled version). Similar to UniInt failover (interfaces), failover should be data source specific and always favor the data source in the better state.
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 36 Declined

Fix calculation so they dont say CALCULATION FAILED since latest update. only is an issue when now button is selected. they work fine when scrolling through history.

everyone
Guest 5 days ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status
210 VOTE

Monitoring Connector health

Support for health tags (similar to UniInt health tags), Windows performance counters, or any other way to bring Connector status and health information into PI tags to put them side-by-side with Interface health monitoring.
Guest over 3 years ago in PI Connectors / General 42 Declined

Allow Units of calculations to be used in displays, not only on top but to the right, left or below.

A tag is giving a simple calculation e.g. TAG_MW * 1. But the calculation has no where to specify the engineering units and it also does not derive that MW * 1 will still be MW. When you place this on the diagram you cannot place the units to the ...
Guest 13 days ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status
125 VOTE

Develop an interactive INI editor for the UFL Connector

The editor should allow you to see in real time how it interacts with the data. Being able to test the INI file prior to loading some file would make it much more manageable to read a variety of data format and insure that it has the expected beha...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for UFL 8 Declined
119 VOTE

PI OPC UA Connector Array support

Add reading capability for OPC UA Arrays. Currently items with “ValueRank“ = 1 are ignored.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 11 No status
108 VOTE

Support HTTP Token Authentication to a REST Endpoint

The REST endpoint from which I want to pull data requires token authentication. I would like the UFL Connector to be able to obtain the token given the username and password I enter on the Admin page.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 6 No status

Support move/rename of Attributes specified by path in Asset-based Calculation expressions

Currently, if an element or attribute is moved or renamed, any Asset-based Calculations in PI Vision with an expression that uses an AF path containing that element or attribute will return "No Data" as it is no longer be able to find that attribu...
Jason Lu 2 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Retrieve data even it's not changed on OPC server

Currently Connector configured to rertieve event on change and not based on a scan class like interfaces.The Connector suscribes to the changes, and when a change comes in to the server, the data will be sent to PI connector. We need option to ret...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 13 Declined

Allow restarting on a data source basis instead of having to restart the connector

Example 1 - OPC If a new connection needs to be made to one OPC Server, restarting the connector forces all data sources (and potentially connections to multiple OPC Servers) to be restarted. Example 2 - UFL If my web service is down and I do not...
Gabriel Verreault over 3 years ago in PI Connectors / General 3 Declined