Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 470 of 5217
344 VOTE

Connector-level Failover - OPC UA 2.x

Support connector-level failover in PI Connector for OPC UA 2.x (relay-enabled version). Similar to UniInt failover (interfaces), failover should be data source specific and always favor the data source in the better state.
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for OPC UA 36 Declined
210 VOTE

Monitoring Connector health

Support for health tags (similar to UniInt health tags), Windows performance counters, or any other way to bring Connector status and health information into PI tags to put them side-by-side with Interface health monitoring.
Guest over 3 years ago in PI Connectors / General 42 Declined

Allow mapping of OIDC clientcredential to multiple identities for Data archive

Currently, when you create a mapping in PI Data archive for OIDC client credentals, you can only assign one identity.This severely limits the granularity and forces to add new identities to existing tags to grant extra permissions and is an easy s...
Peter Speybrouck about 1 month ago in AVEVA™ PI Server / Security 0 No status
125 VOTE

Develop an interactive INI editor for the UFL Connector

The editor should allow you to see in real time how it interacts with the data. Being able to test the INI file prior to loading some file would make it much more manageable to read a variety of data format and insure that it has the expected beha...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for UFL 8 Declined
119 VOTE

PI OPC UA Connector Array support

Add reading capability for OPC UA Arrays. Currently items with “ValueRank“ = 1 are ignored.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 11 No status

Allow AIM to directly authenticate users from other Identity Providers without CONNECT

Currently, AIM can only use CONNECT or Microsoft Entra ID as the main Identity Provider. Configuring any other IDP requires federation through CONNECT. Allowing other IDPs to work directly with AIM without CONNECT would simplify the OIDC configura...
Dan McGovern 22 days ago in AVEVA™ PI Server / Security 0 No status
108 VOTE

Support HTTP Token Authentication to a REST Endpoint

The REST endpoint from which I want to pull data requires token authentication. I would like the UFL Connector to be able to obtain the token given the username and password I enter on the Admin page.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 6 No status

Retrieve data even it's not changed on OPC server

Currently Connector configured to rertieve event on change and not based on a scan class like interfaces.The Connector suscribes to the changes, and when a change comes in to the server, the data will be sent to PI connector. We need option to ret...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 13 Declined

Allow restarting on a data source basis instead of having to restart the connector

Example 1 - OPC If a new connection needs to be made to one OPC Server, restarting the connector forces all data sources (and potentially connections to multiple OPC Servers) to be restarted. Example 2 - UFL If my web service is down and I do not...
Gabriel Verreault over 3 years ago in PI Connectors / General 3 Declined

OPC UA: allow historical data access

allow historical data access with custom time ranges, like OPC HDA
Clint Ramsey over 3 years ago in PI Connectors / PI Connector for OPC UA 11 Declined