To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI to PI Interface

Showing 17

Enable the ability to use the UserInt1 to propagate PI to PI APS source tag name changes to the target if source collective Data Archive-level failover is configured

UserInt1 attribute contains source point ID. (Illegal configuration if source Data Archive-level failover is configured.) Source tag mapping by point ID is not compatible with Data Archive-level failover.
Guest 9 months ago in PI Interfaces / PI to PI Interface 0 No Status

Supress PI-APS messages for Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table

Seeing "information" messages in PI-SDK related to "Error -2147220428: Failed to create point on server. [-10550] Tag Already Exists in Table" which is irrelevant to see in the logs. If one source instance sending to multiple destination instances...
AshwinC 11 months ago in PI Interfaces / PI to PI Interface 1 Future Consideration

Enhance pitopi.ini sections to include point source to make them unique

The pitopi.ini file is used by the pitopi interface for collecting data from multiple sources and to save other miscellaneous settings such as 'histonly' flags. The configuration ini file uses sections to separate settings between instances with a...
Guest over 1 year ago in PI Interfaces / PI to PI Interface 2 No Status

Enhance connection logic to source PI server during Interface startup

When PitoPi Interface starts up, it prints a message saying that it secured a connection with the Target or Host PI server as follows:  PIAPI Successfully connected to :5450. Then it begins to load target PI points and it starts looking for the so...
Guest over 1 year ago in PI Interfaces / PI to PI Interface 0 No Status

PI ICU should not allow PItoPI COLD failover configuration

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, the PI Interface configuration utility still allows COLD failover to be selected....
Guest over 1 year ago in PI Interfaces / PI to PI Interface 0 No Status

PItoPI should switch from COLD to WARM failover instead of exiting

As of version 3.8.1 COLD failover is no longer supported by the PI to PI Interface (https://techsupport.osisoft.com/Troubleshooting/Enhancements/19255OSI8). However, older versions supported COLD failover. In the case of upgrading the interfaces, ...
Guest over 1 year ago in PI Interfaces / PI to PI Interface 2 No Status

For PItoPI interface having a source PI-HA server, allow failover on source without using PI interface status utility.

For PItoPI interface having a source PI-HA server, allow failover on source without using PI interface status utility. This should allow failover based on connectivity and/or a watchdog (like failover if a specific tag stay stale for a configurabl...
Guest over 1 year ago in PI Interfaces / PI to PI Interface 0 No Status

Add functionality to the interface to adjust timestamps by a configurable amount

This enhancement would add the ability to adjust timestamps to the PI to PI Interface (Beyond the included options for clock drift and subseconds). Potentially, a setting could be supplied to change the timestamps on all data transferred by a spec...
Guest over 1 year ago in PI Interfaces / PI to PI Interface 1 No Status

Annotations support in PItoPI

Annotations are crucial in some instances. PItoPI should be able to handle annotation duplication.
Alan Izar over 1 year ago in PI Interfaces / PI to PI Interface 3 No Status

PItoPI should give indication when it is stuck querying a corrupt source archive

Currently, PItoPI interface can get "stuck" if it is querying a source data archive that is corrupt with no indication that this is what's happening.  It appears to be sending data to the destination server, but no data is received.  It would be h...
Guest over 1 year ago in PI Interfaces / PI to PI Interface 1 No Status