Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Other specific PI Connector

Showing 47

PI Connector for IEC 60870-5-104 writes 'No Data' or another SYSTEM digital state when connection to the Data Source is lost.

This connector is specially used to monitor the connection of the machines, but if there is a general network crash, and the connector losses the connection to the Datasource, it will stop sending data instead of sending something to alert of the ...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 Declined

Apply the Connector Relay to IEC 60870-5-104 Connector

Adding the Relay and the DCM framework to the "legacy"IEC 104 Connector in order to improve the architecture management and security
marcogiunti over 2 years ago in PI Connectors / Other specific PI Connector 1 Declined

Allow specification of PI Point Attributes set by the PI Asset Connector for Emerson DeltaV 3.X

The PI Asset Connector for Emerson DeltaV 3.X sets PI Point Attributes either based on the values in the enterprise historian configuration file (EntHist.xml) or based on default values. It would be useful to have the option to adapt the PI Point...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 3 No status

Reduce Number of Point Sources for PI Connector for PI System Health

PI Connector for PI System Health creates a LOT of different point sources for the Pi points it creates on the Data Archive. Some customer may prefer to not have so many point sources show up for one interface/connector. Adding a method to reduce/...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 2 No status

PI Connector for IEC 60870-5-104: to filter IOAs

Considering the following scenario encountered by the customer: In IEC-104 data source, there might be 500 signals of single point (type=1, M_SP_NA_1) and 1000 measurements of normalized value (type=9, M_ME_NA_1); however the customer would not l...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 3 No status

Redundancy for PI Connector Relay

Operating in a validated pharmaceutical industry, when making use of a comprehensive data/asset centralizing approach, we require the PI Connector Relay to be redundant or highly available. We are currently in the obligation to deploy the PI Conne...
Christian Leroux almost 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Enable setting tag attributes in MQTT Connector

The MQTT Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status

Further development of OMF

In OMF unfortunately more complex use cases are not possible Integration of Script functionally for generated elements from OMF are needed. Please insert an possibility or allow an other development method to use all AF functionality in case of ge...
photi24 over 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Adjust GE e-terraHabitat Connector to support e-terraPipeline systems

The Pi Connector for GE e-terraHabitat systems was apparently only written to support GE's Electrical SCADA systems (EMS/DMS) that are based on e-terraHabitat. They also have Oil & Gas Pipeline SCADA systems, also based on e-terraHabitat, know...
KPRoth over 2 years ago in PI Connectors / Other specific PI Connector 0 No status