Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 6

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 Planned

PI EMDVB Interface should not use the STARTUP.dat to determine recovery start time when configured in Failover and running in RealTime mode.

Currently when the PI Interface for Emerson DeltaV Batch (EMDVB) is configured for failover and running in RealTime mode, the interface will use a recovery start time (RST) based on the last time the interface was active. This results in the inter...
Bethany Jewett almost 2 years ago in PI Interfaces / Batch Interfaces 2 Planned

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Allow the PI Point description to not be populated by the adapter

Implement a configuration flag that allows one to NOT synchronize description from OPC UA server into PI Tag. In instances where the description is empty "", the description cannot be set in PI. Similarly, the description on the OPC UA Server sid...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 15 Planned

Batch Framework Interfaces - [TIME] placeholder should consider whether TS=LCL is configured

Batch Framework Interfaces - [TIME] and [TIMESTAMP] placeholders should consider whether TS=LCL is configured (meaning the interface is processing incoming events as Local Time). Currently, values of these placeholders always show up as GMT timest...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 5 Planned

OPC DA Interface to run on Microsoft Visual C++ 2015-2022

Can only install OPC DA Interface (2.7.2.20) with "Microsoft Visual C++ 2015-2019 Redistributable" installed.
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 Planned