To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

General

Showing 25

Include [optional] unit of measure in the data selection configuration.

Some data sources do not provide a unit of measure. It would be useful to be able to specify the unit of measure as part of the data configuration so that this information is provided to EDS/PI/ADH through the data flow.
Mike Horrocks about 1 month ago in AVEVA™ Adapters / General 0 No Status

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins about 2 months ago in AVEVA™ Adapters / General 2 Already Exists

host adapter(s) as a service

SaaS solution for customers with benefits thereof.
Guest 3 months ago in AVEVA™ Adapters / General 0 No Status

Adapters using Text parser be able to dynamically generate the stream name or ID based on fields of the text parsed

This could be a good feature for any adapters that uses the text parser. MQTT, SDF, Azure Event Hubs. When using JsonPath or Xpath to parse a file or payload the stream name and stream id have to be hardcoded their value cannot be based on a the v...
Randy Giguere 5 months ago in AVEVA™ Adapters / General 0 No Status

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee 5 months ago in AVEVA™ Adapters / General 0 No Status

Allow restricting access to the Adapter to only allow configuration by specific users

We want to make sure that we have more control over who can update an Adapter. Is there a way to add a login or other restriction to only permit certain users to be able to modify Adapters, similar to how, with PI Connectors, only specific Windows...
Daniel Lopez 6 months ago in AVEVA™ Adapters / General 1 No Status

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee 7 months ago in AVEVA™ Adapters / General 1 No Status

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
GaryYegiazaryan 9 months ago in AVEVA™ Adapters / General 1 No Status

Permit non-protected references

The secrets references is a very useful addition but they are only permitted for "protected" parameters. It would be useful to also create references for non-protected parameters. Using references for non-protected parameters would help with creat...
Mike Horrocks 9 months ago in AVEVA™ Adapters / General 0 No Status

PI Adapters should not overwrite parameters configured in the stream in ADH

When we change any override parameters for a stream in ADH an adapter restart will overwrite what we configure in the stream. One example is changing the interpolation method for a stream in ADH because we want to see the trend as step. Every time...
Fabio Dani 10 months ago in AVEVA™ Adapters / General 0 No Status