To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

AVEVA Adapter for Modbus TCP

Showing 6

Failover support for Adapter for Modbus TCP

This is a new idea for the failover functionality specific to the Adapter for Modbus TCP. Copied from the original idea (https://pisystem.feedback.aveva.com/ideas/PIADAPTERS-I-23): As a customer, I need to ensure that the primary instance of the a...
Jiyeon Hwang over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 1 Planned

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest 10 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Accept HEX numbers for Register offsets in data selection

Most modbus equipment providers provide information using registers in Hex format i.e. 0x0000 ~ 0xFFFF. It would be nice if the offset could accept this to avoid error in conversions HEX to DEC. Would make things alot more seamless/easier.
Matthew Kishe almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration