To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 88 of 5197

Support dynamic OPC addresses

My OPC server's items have the OPC server node name included in the itemID, for example: serverA.AB_1234.PV. I have redundant OPC servers and redundant interfaces (in failover) and would like the tags to refer to the correct OPC address including ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Interface should reload performance counters after failover and keep track of them.

The interface should be designed to reload counters both at startup and when becoming the active interface after a failover. The interface should realize the counter is not available and periodically attempt to reload (ideally with a message to th...
Nicolas Capera Choconta over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Changing Units of Measure (UOM) for non-AF Points

Our Data Archives have all tag UOMs synced with our AF UOM Databases, to enable us to correctly utilise standard conversions for all points. We were delighted with the PI Vision 2022 feature to change UOMs for AF Attributes, but this feature shoul...
SteveTaylor about 3 years ago in AVEVA™ PI Vision™ / AF Integration 0 No status

Add default PI Vision trend configuration to AF server template attributes

Add the ability to provide default trend configuration (colors, etc) to template attributes in AF server. For example, I always want my attribute "B phase amps" to be green when it's added to a trend. This could possibly also be done for categories.
rdb6777 about 3 years ago in AVEVA™ PI Vision™ / AF Integration 0 No status

"Set as root" for PI AF Databases in PI Vision tree

When permitting PI AF Databases to PI VIsion in the PIVision\Admin tool, could there be an option to select an asset and "set as root" as you can do in PI System Explorer - so that the PI Vision users do not see the whole asset tree - but the asse...
Martin Bryant over 2 years ago in AVEVA™ PI Vision™ / AF Integration 1 Already exists

Support AF SDK Bulk calls for custom data reference

As a custom data reference developer, I would like my bulk AF SDK call implementation to be supported in PI Vision as this should improve the custom data reference performance when multiple custom data reference attributes are in the same display.
Guest over 3 years ago in AVEVA™ PI Vision™ / AF Integration 1 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Preferring a primary interface failover member

hen the primary Interface becomes available and healthy again, it becomes "back up". I need the primary Interface to become the "primary" whenever it is healthy. https://pisquare.osisoft.com/thread/42591-revert-back-to-primary-data-collector
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status