Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Include the "Include variables having historical data only" flag for the OPC UA Adapter

The OPC UA Connector has a feature that should also be included with the AVEVA Adapter for OPC UA : UserAccessLevel=HistoryRead - No real time data to subscribe for and only has historical data stored Please add this feature to the adapter.
Joshua Weishaar 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
GaryYegiazaryan about 3 years ago in AVEVA™ Adapters / General 2 No status

Allow session persistence to support true QoS 2 data collection and backfill of events after a data source disconnection

It appears that regarding Session Persistence (persistent vs clean session), the Adapter hardcodes setting the Clean Session Flag for the generic data source (Sparkplug doesn’t QoS 2 nor session persistence) to true. This should be a user-defined ...
Daniel Lopez 5 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Invalidating data in PI Vision

As a PI Admin, we need to invalidate data that we do not believe is valid.  This can be a real pain to do in SMT and would be much more user friendly if we could highlight a trend of where we deem the data invalid and have it flag the data as...
kimmyberly26 about 4 years ago in AVEVA™ PI Vision™ / AF Integration 0 Declined

Direct visualization on PI Vision of the correspondence PI tag/asset atribute

This "feature" is very useful for all users (specially Operations) when we change from ActiveView to Pi Vision. The transition period must be taken in account. It will be an extra if OSI can develop the visualization of some more detail informati...
Nuno Pacheco about 4 years ago in AVEVA™ PI Vision™ / AF Integration 0 Declined

View data across AF Element Versions

Handle the ability to trend data from attributes across AF Element Versions.  For example, when old sensors have been replaced with a new control system, new tags are created and customers use AF Element Versions to manage the mapping betwe...
Guest about 4 years ago in AVEVA™ PI Vision™ / AF Integration 2 No status

Enable TLS Configuration

As a customer I want HTTP and HTTPS support for Edge DS so that I can configure the appropriate level of transport security for my deployment
Guest about 4 years ago in Edge Data Store / General 2 Declined

OMF: Swagger Specification

I think it would be beneficial to have a Swagger Specification for OMF similar to what currently exists for the PI Web API. As a programmer, I would like to be able to reduce startup time by having a pre-existing libraries that allow me to reduce ...
Guest about 4 years ago in Developer Resources / Open Message Format (OMF) 1 Declined