To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

PI EFGen 4.1+ has limited recovery capabilities

Up to PI EFGen 4.0, we were able to backfill OOO Event Frames by simply inputting the start and end time of the corresponding period. Since 4.1, this must be done in a per-event basis, since larger time ranges are modified so that RST matches the ...
Guest almost 4 years ago in PI Interfaces / Batch Interfaces 1 No status

DeltaV Smart Connector configurability

Smart Connector foo DeltaV should let user configure some default attributes for tags created: - User should be able to define what the default point security should be - User should be able to decide if tags should be created as Poll or Advise
Guest almost 4 years ago in PI Interfaces / Other Interfaces 0 No status

Add a Trace Route feature to PI Ping interface

Add ping -i feature to the interface and allow for either the output of the ping time or destination in the PI tag. Case: This will allow for IT to monitor the network path taken in communication from one site to another. If the route has change...
Guest almost 4 years ago in PI Interfaces / Other Interfaces 0 No status

Subsecond Cropping for Improved Timestamp Handling

The OPCDA interface currently can only handle subsceonds by ignoring them as mentioned in "Ignore Subsecond Timestamps" under PI Interface for OPC DA - Data Handling settings. However there are use cases where users would like to simply limit the ...
Mohammed Shahin almost 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Batch interfaces keeping merged child operation EventFrames open until the parent Operation EventFrame has been closed.

Currently for batch interfaces using the /MUP parameter, child operation event frames might be reopened and closed multiple times until the last operation event frame closes and the child event frame is closed for good. For example with UnitProced...
Guest over 2 years ago in PI Interfaces / Batch Interfaces 0 No status

Add Standard Deviation and Difference to Summary Table of the Ad Hoc Workspace

This helps with basic statistical analysis, and supplements statistics already there (average, minimum, maximum). Process Engineers and other analyst-type roles would use this. The Difference is between the ending and starting values of the trend.
kazimmohammed over 3 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 1 No status

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco over 3 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

PI Interface for Ramp Soak Simulator Data - Update Time Period To Seconds

To simulate data using the PI Interface for Ramp Soak Simulator Data, the ExDesc of the PI Point needs to be of the format: (period, end_value) period is the time in minutes. end_value is the value for the tag at the end of the phase period. Cur...
Mohammed Qasim Asghar over 1 year ago in PI Interfaces / Other Interfaces 0 No status

Export data in kiosk mode

A display that is in kiosk mode no longer has the option to export data to an XML file. Adding this feature would be useful whenever the vision display is embedded in another website.
Guest almost 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 1 Declined

Ability to see multiple incremental scales in adhoc display

Right now you can have multiple scales but for all but one scale only the min and max value are displayed on the trend. Would be helpful to have incremental scale values for all scales displayed at the left of the trend. For example in the attache...
Guest almost 4 years ago in AVEVA™ PI Vision™ / Ad Hoc Analysis 1 No status