To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 180 of 5209

Allow configurable PI Point Lookup priority whether to use PI Point name or PI Point ID first

Currently, in PI Vision display, PI Points data items are stored using both the PI Point ID and PI Point Name. During data retrieval, PI Vision prioritizes resolution via PI Point ID and only falls back to PI Point Name if the PI Point ID is not f...
Mohammed Al-Shaikh 2 months ago in AVEVA™ PI Vision™ / Administration 0 No status

Allow remote configuration

Adapters are currently only listening on localhost (127.0.0.1) causing them to be only accessible locally. For docker containers, they can only be accessed from within the container or directly on the host (with the --network host switch which res...
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / General 3 Future consideration

Identification of unused PI Vision displays

Currently the PI Vision "Display usage information" report only shows displays that have been accessed at least once. It should also show displays with zero accesses, which are an indication that they might not be needed anymore. By identifying un...
victor.guiotoku about 1 year ago in AVEVA™ PI Vision™ / Administration 0 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Support https instead of http only

No description provided
Gabriel Verreault over 3 years ago in AVEVA™ Adapters / General 2 Future consideration

PI Adapter for OPC UA should poll a series of items based on a trigger events

Same as the PI Interface for OPC DA feature with "Trigger Tags", the idea is to poll for updates on a series of item streams (tags) only when a certain item stream updates. The benefit of this is to create timestamp alignments between a series of...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Vision - AIM login page to fully disable Windows AD login, and only allow OIDC

Currently, with Vision + AIM OIDC, during AIM login when accessing the Vision, we can still enter Windows AD credential and successfully login to Vision provided there's an OIDC mapping for the Windows AD credential This can be very confusing for ...
Ee Sheing Lee 3 months ago in AVEVA™ PI Vision™ / Administration 0 No status

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi 8 months ago in AVEVA™ Adapters / General 0 No status

New access level to restrict display sharing

We need a new access level with below privileges: - Read shared displays - Create & save displays - No access to share displays with others Most users in Vision like to explore and save their displays. Only access level for that is Publisher. ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Administration 2 Declined

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration