Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 185 of 5259

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Create function / calculation with custom time interval (not just "past 30 days")

Customer frequently utilizes PI Vision calculations but sees a gap with time ranges. They would like the ability to choose precise dates for their functions and calculations, not being limited to pre-set ranges.
Matthew Del Bonta over 2 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Nate Anderson almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

Change the tooltip behavior for asset-based calculation to differentiate from AF Attribute paths

Currently, when hovering over a symbol that displays a PI Vision asset-based calculation, the tooltip that represents the calculation "path" has the same nomenclature/format as an AF attribute. In this case, the format is < Path to AF Element w...
Luis Camacho Forero over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest over 1 year ago in AVEVA™ Adapters / New Connectivity 0 No status

Show calculation inputs with a single action when viewing the calculation result

If one is viewing a calculated value on a trend, for example, it would be helpful to take one step to see the values behind that calculation for troubleshooting purposes.
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 Declined

Create PI ProcessBook Support Tool add-in to replace data sets in PB displays with other data references before migrating to PI Vision

As described in PI System Analytics: Which tool is best for the job? (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB00868), OSIsoft recommends using asset analytics instead of PI Calculation data sets to create calculation...
Jeremy Roberts over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 Declined