Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 177 of 5192

Show calculation inputs with a single action when viewing the calculation result

If one is viewing a calculated value on a trend, for example, it would be helpful to take one step to see the values behind that calculation for troubleshooting purposes.
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 Declined

Create PI ProcessBook Support Tool add-in to replace data sets in PB displays with other data references before migrating to PI Vision

As described in PI System Analytics: Which tool is best for the job? (https://customers.osisoft.com/s/knowledgearticle?knowledgeArticleUrl=KB00868), OSIsoft recommends using asset analytics instead of PI Calculation data sets to create calculation...
Jeremy Roberts over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 Declined

Function Text

Ability to add text containing basic functions (add, subtract, multiply, divide) using data pointing to number assets.
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Auto convert decimals to hours/minuets

No description provided
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Adding the array function in PI Vision / Hinzufügen der Arrayfunktion in PI Vision

To display the last 10 product data to see if the last 10 products were compliant or what defects they had. Or to display the sum of a number in certain time intervals (hourly table to see the last 24 hours of production hourly) or the sum of the ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status