To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi over 1 year ago in AVEVA™ Adapters / General 1 No status

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest almost 4 years ago in AVEVA™ Adapters / General 7 Future consideration

Send only data that has changed.

When transferring data via satellite it is necessary to keep bandwidth usage to a bare minimum. Currently OMF must send all values regardless of whether they have changed or not. If it could send only the data parameters that have changed that wou...
Guest almost 4 years ago in Developer Resources / Open Message Format (OMF) 6 Declined

PI to Connect Agent instance Failover

on behalf of customer: We would like to see agent failover added to PI to Connect. The PI System already provides high availability, and extending this capability into PI to Connect would deliver a resilient hybrid infrastructure end-to-end. Histo...
omar alomari 9 months ago in PI to CONNECT / General 1 No status

Add option to view user's effective permissions or view CONNECT as user

For data sharing with orgs that are not PI users, they would have to be added to the existing org's tenant. In this use case it is difficult to verify that a user has correct permissions and can only see data intended for them without using a test...
Adam Bolin 6 months ago in PI to CONNECT / General 0 No status

Allow Definition of Point Attributes via OMF to PI Web API

When creating containers via OMF the PI Points are created with default Point Attributes - if these need to be changed it is a manual process to subsequently change the attributes appropriately. As OMF solutions can be easily deployed it would be ...
Guest almost 4 years ago in Developer Resources / Open Message Format (OMF) 2 No status

Native MQTT Publishing (Egress) to Support Unified Namespace (UNS) Architectures

Description & Use Case: As the manufacturing industry shifts toward Industry 4.0 and Unified Namespace (UNS) architectures, data must flow seamlessly between all systems in a publish/subscribe model. The AVEVA PI System is exceptional at inges...
Mandeep Sidhu 5 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Support move/rename of Attributes specified by path in Asset-based Calculation expressions

Currently, if an element or attribute is moved or renamed, any Asset-based Calculations in PI Vision with an expression that uses an AF path containing that element or attribute will return "No Data" as it is no longer be able to find that attribu...
Jason Lu 9 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration