Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Provide option to add multiple tabs in a PI Vision Display

As a PI Display Author I want to have the option to create different tabs in a Display. Each tab could have different content in the same Display ID. This would allow us to use the limited space of a web page. setttings like search selected elemen...
meierke1 about 4 years ago in AVEVA™ PI Vision™ / Display Management / Displays Page 0 Declined

PI Vision Display Utility: Copy displays between PI Vision databases on the same machine

The 2019 PI Vision Display Utility was changed so that displays from a PI Vision Server cannot be copied over to a different database on the same PI Vision Server. We keep a backup of the PI Vision SQL database on the same machine as PI Vision in ...
Guest about 4 years ago in AVEVA™ PI Vision™ / Display Management / Displays Page 1 No status

Check if source PI Data Archive/AF Server is a stored server reference in display utility

When changing AF or PI Data Archive server names using PI Vision display utility, check if the source entries for the servers are stored server references for the displays. In case, I don't specify the correct source server name (FQDN vs hostname)...
Guest about 4 years ago in AVEVA™ PI Vision™ / Display Management / Displays Page 0 No status

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Gabriel Verreault about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest about 4 years ago in AVEVA™ Adapters / General 0 Tell us more

Support an analogue to the "step" PI Point attribute when creating PI Points

Even though it will indeed be useful to be able to specify whether data should be retrieved in a step-wise fashion, for new PI Points (assuming you're writing data to a PI Connector), it's important to be able to specify that those tags should hav...
Guest about 4 years ago in Developer Resources / Open Message Format (OMF) 1 In development

An option to store symmetric keys in a file - OPC UA

It would be helpful to be able to read network trace between OPC UA Server and Adapter even if communication is encrypted. This possibility is described here https://www.unified-automation.com/news/news-details/analyzing-encrypted-opc-ua-traffic-w...
Mateusz Dura 4 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 4 Tell us more

Ability to Explicitly Define Cloud Data Type for Modbus TCP Data in Edge Data Store

Description / Business Context I am currently using AVEVA Edge Data Store with the Modbus TCP interface to collect data from industrial devices and forward it to CONNECT Data Services (CDS). For each Modbus data selection, the Modbus configuration...
Guest 4 months ago in Edge Data Store / Egress 0 No status

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 8 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status