To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 494 of 5194

Root NodeID 255 character limit

For the PI Connector OPC UA configuration, the Root NodeIds field can only accept a maximum of 255 characters currently. This is seriously limiting if we need to gather a lot of data from many pieces of equipment
Guest over 3 years ago in PI Connectors / New PI Connector Request 1 No status

Create a PI connector/interface for devices communicating using the BACnet/SC protocol

The instance of the PI system that the group I work in is over 50% complete in integrating the JCI Metasys building control systems from 190 facilities. The software/firmware of the devices that comprise the JCI Metasys system we are using current...
Daniel Chiariello over 1 year ago in PI Connectors / PI System Connector 0 No status

Flexibility in configuring the DescriptionField tag (<DescriptionField value="TEXT"/>)

PI-Connector-for-GE-e-terrahabitat-1.1.1.42 Currently, the Connector for e-terrahabitat only allows the configuration of the Description Field to return only data from the TEXT field and PNTNAM table. The configuration of the Description field nee...
Guest 9 months ago in PI Connectors / Other specific PI Connector 0 No status

PIVision user to associate event frames with each other (Root cause and effect)

Event frames are often correlated with one another. "This caused that." One event was the cause for another. These associations are valuable human input, actually they represent discovery of latent issues and growth. To capture the leading edge in...
Steve Edwards almost 3 years ago in AVEVA™ PI Vision™ / Events (EF) 1 No status

Automatically updating digital state sets with PI System Connector

Add a feature to the PI System Connector so that it updates automatically digital state sets on the Destination Data Archive when edited on the source Data Archive. Currently PI System Connector replicates digital state sets referenced by the PI p...
Guest over 2 years ago in PI Connectors / PI System Connector 0 No status

Permission different users to comment and acknowledge event frames.

Some users need to comment event frames but they should not be allow to acknowledge them. The permission Annotate allow both comment and acknowledgement feature. Please enable specific permission configuration so we can give accurate permission to...
Emmanuelle about 3 years ago in AVEVA™ PI Vision™ / Events (EF) 0 No status

Support synchronizing multiple AF databases with PI System Connector

A customer needs to replicate the data and AF models from a secured PI Server to a second PI Server on the business network. The PI Server has 3 or 4 AF databases because the AF models are segregated by function. Currently the PI System Connector ...
Laurie Dieffenbach over 2 years ago in PI Connectors / PI System Connector 0 No status

Specify time bar increments for event frames in Event Details page

Currently the Time Bar Duration is determined by the event duration and the event duration determines the time increments of the trend. Therefore the time increments will be greater for a longer event frame.
Guest over 1 year ago in AVEVA™ PI Vision™ / Events (EF) 0 No status

PI System Connector should be able to Parameterize AF objects (like attributes) to dynamically update between environments

In Asset Framework, we are able to use substitution parameters to define PI Point Data References because the variable is able to resolve based on the template. PI System Connector is used to synchronize, and keep perfect copies of the assets betw...
zachary cmelak 10 months ago in PI Connectors / PI System Connector 0 No status

Add possibility to Configure purge time/output path/REST channel authentication in the admin/ui webpage without GlobalConfig.ps1

It's more complex and not the safest way to change the PurgeTime and OutputPath parameters with GlobalConfig.ps1 by specifing password in command line. It would be better if this option would be availble for UFL admin on the admin/ui webinterface....
Yuriy Sadovskiy over 1 year ago in PI Connectors / PI Connector for UFL 0 No status