To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 162 of 5197

IEC61850 - Support connection to servers requiring custom COTP parameters (network addressing)

The connector should be able to define all the COTP parameters to connect to IEC61850 servers.
Gabriel Verreault over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Enable GE Habconnect default attributes by query

Newest version of the GE HabConnect Connector supports default point attributes to be added at the field level. However, many attributes are set at the query level -- security for example. In addition, some installations potentially require dozen...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Support delayed startup of queries for GE HabConnect Connector

In some EMS configuration it is possible that to connect and query sampler before habitat database has initialized. This can cascade throughout PI -- analytics set to watch for minimum values, applications looking for status changes, etc. It is al...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

PI Connector for PCS 7 - Alarm & Events with same timestamp

The current version can't store alarms with same timestamp in the same PI Point. Unfortunately, this is the expected behavior of the Connector for PCS 7. This happens because of the mode the data is sent to the PI System (UPDATE mode which overrid...
gweissflog over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

IEC 60870-5-104: Interrogation Period

Currently, the PI Connector for IEC 60870-5-104's Interrogation Period (for each data source) can only go as low as 1 hour. As a PI System Administrator, I'd like to be able to set this value lower (on the order of seconds) so that all PI Points ...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

Informationen based on Zoom Level

Would be nice, for hugh overviews, to have the ability to define what is shown on the display based on the zoom level
meierke1 over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 Declined

Referenced Elements in PI AF

We have a referenced Elements created In PI AF. We see the referenced elements has the same Element ID. Currently there is not flag to differentiate the Original Element from the Referenced Element. In PI AF it has a little arrow which tells us it...
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 Declined

Add current timestamp to trend if end-time is in the future

current timestamp in trend
ArieVanBoven over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 Declined

Provide sample ISA 101.01 2015 style symbols with XY plot support (More modern symbols)

Apologies that this overlaps a number of earlier submitted requests, but I realised you cannot attach a file to a comment, so created a new post. The symbols were updated for PI Vision 2017, but it is still difficult to create the dynamic symbols...
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 1 Declined

Dynamic Trend scale

When you select a variable on a trend with multiple scales, the scale displayed at the left should change to that of the selected variable.
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 Declined