Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 41 of 5194

Apply PI Vision folder security to Destination folders when migrating ProcessBook displays

Currently any user in the PI Vision Utility Users group running the PI ProcessBook to PI Vision migration utility can select any folder as the destination folder, regardless of whether they are allowed to write to the folder in PI Vision (i.e. the...
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

Trend with digital state, show only digital state for scale, it should allow number like before in Processbook

In Processbook, when we draw a trend with multiple digital tag, we can set multiple scale with the number of the state. This permit to see multiple tag with the same scale on different place in the trend. When we define the trend we see only the d...
LGaudreault over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 1 No status

Allow configuration of the PI OPC DA Server's ProgID

The ProgID of the 2015 PI OPC DA Server is OSISoft.OPCDA2.DA.1, while the ProgID of the 2010 PI OPC DA Server is OPC.DA.1. Existing client tools that pointed to the 2010 PI OPC DA server will need to be reconfigured to point to the new ProgID aft...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 3 Declined

Support Cross Domain authentication for PI Processbook to PI Vision 2019 Migration Utility

On an architecture with Utility on a computer located on a different domain of the PI Vision server, the authentication fail. Could it be possible to prompt a login window (as for AF)
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 3 No status

Distinguish between types of OLE objects during the migration analysis

Currently if a .PDI file contains an OLE object, which could be something as simple as an image embedded in the file using Insert > Object in ProcessBook, the OLE object can't be migrated. The Analysis Results return a warning that the "File co...
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

Vision migration of Processbook custom trend axis

Support Custom axis settings. to avoid this current issue "Unsupported legend option;Custom axis settings are not supported;Scales with different max and min types are not supported.;Trends with different trace scale ranges are not supported unde...
Matt Voll over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 1 No status

Add feature for PB to PI Vision Migration Utility to use local folder if target linked display cannot be resolved.

As PI Vision admin I have to migrate ProcessBook displays from several users throughout the company. There is no easy way to open each display and check if the target display path is valid and fix via PI Processbook Support Tool before running the...
Alex Santos over 2 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

Add OPCclient to all PI OPC DA server install kit

In verifying the OPC DA server DCOM setting you need to use the OPCclient to check PI tags values. In the OPC DA server 2017 you need the latest version of OPCclient (was not in OCP client tools) to allow to connect correctly to the OPC DA server ...
davidrosinski over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 4 Declined

Be able to expose AF with PI OPC DA Server

Today PI OPC DA can only expose tags from DA. To have the option to expose information from AF. Both the AF structure and attributes. We are using AF for everything so why not in PI OPC DA.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 3 No status

PB to Vision Display Migration Utility: Add support for UNC style file paths

Some organizations are discontinuing the use of mapped drive letters since they are a known cyber attack vector and are instead using UNC file paths (eg. \\fileserver\share) to access network shares. There is no way to navigate to a network locat...