To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 155 of 5258

Future Data Attribute Limits

We are utilizing future data and would like to utilize a Limit on a formula that uses future data. However my static limit does not extend into the future like I think it should. My goal is to see what future dates my temp might exceed my limit. I...
ehoffman over 3 years ago in AVEVA™ PI Vision™ / Reporting 0 Declined

Have Multi-state for multiple pi points associated to a single visual on a vision screen

Would like to have multi-state coloring for a given visual where 2 or more pi points/values can contribute to that equipment's current state.
Borgh over 3 years ago in AVEVA™ PI Vision™ / Reporting 0 No status

Make it easy for an end user to export aggregated data

Its currently not end-user friendly to export things like 10 minute averages from PI Vision. Users regularly mention how they would like this feature, or things like Daily Averages or Daily Totals. This would help PI Vision become more of a one-st...
alan.mccarthy over 3 years ago in AVEVA™ PI Vision™ / Reporting 0 No status

Event Frame Acknowledgement Summary

It would be very useful to have a function in PI Vision which counts the number of event frames still ‘to be acknowledged’ for an asset and show this in a table (ideally with conditional formatting).
Guest over 3 years ago in AVEVA™ PI Vision™ / Reporting 0 No status

read files from AWS S3, Azure storage and Google Cloud Storage

For example, model inference data is written to storage and required destination is a PI System.
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Nate Anderson almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration