Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Allowing the MQTT adapter to set PI Point attributes during the creation process

we're interested in having the ability to configure the zero, span and some other points parameters during the creation of the PI points. currently when points are created. they're defaulting to zero=0 and span=100. while also displaying Boolean p...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration

LOTOS PJ

If you align value items to left or right it does not work in longer period of time. The items move depending on digit numer displayed (attachement VALUES): 1. Good to have option set decimal digits, 2. Good to have option TEXT SIZE, 3. Do not cha...
Guest about 4 years ago in AVEVA™ PI Vision™ / Reporting 1 Declined

Write business data to PI Vision display

To be able to add business data coming from existing business systems into PI Vision displays.
Guest about 4 years ago in AVEVA™ PI Vision™ / Reporting 0 Declined

DCD alarm report

NEXT TO TRACK DCD EVENTS AND RUN A REPORT WEEKLY/ MONTHLY/YEARLY WE ARE TRACKING IN ADMS AND NEED A WAY TO SEND VIA EAMIL. scada point ids Bin 00014-00018 on reclosers. Paul Unrast
Guest about 4 years ago in AVEVA™ PI Vision™ / Reporting 0 No status

Felaktig signal.

PK051 ÖVY signal är felaktig, det är PK042 ÖVY som är inlagd i Översikt Luleälven. Med vänlig hälsning Jerry Rutström
Guest about 4 years ago in AVEVA™ PI Vision™ / Reporting 0 No status

AVEVA Adapter for WITSML

We need an Adapter for WITSML to get data from drilling, completions, and interventions of oil wells to CONNECT data services, so the data can be shared between multiple stakeholders.
Guest over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status