To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 371 of 5194

Bad value indicator

Have a bad value indicator on value symbols - A triangular indicator specially in the value symbol which would indicate an exclamation mark when the quality of the data value is bad.
Ryan McErlean over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Add events table to collection

To be able to have event tables within Collection (this is mandatory) Event tables are feed with events matching the collection asset. It is different than the idea https://feedback.osisoft.com/forums/320517/suggestions/35062504
Gael over 3 years ago in AVEVA™ PI Vision™ / Symbols 1 No status

Single Gauge with Multiple Values

Configure gauges using multiple attribute values. As an example, if you have a tank that has 2 level sensors, it would be helpful to show both levels in 1 gauge. Currently we accomplish this by creating 2 gauges and putting 1 on top of the other, ...
holemn over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Plot markers for all archived events for step tags

When plotting a tag with the "step" attribute on in a PI Vision trend with the scatter plot trace option, not all archived events are shown. A workaround is to create a Formula Data Reference attribute in AF that points to the tag with the stepped...
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

XY Plot: Numerical formatting of scale

Allow formatting of numerical values used in the scale to be configurable. E.g. use display digits set on attribute or be able to specify number of decimal places. Currently number formatting only affects the values that appear in the tooltip.
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

DeltaV Smart Connector configurability

Smart Connector foo DeltaV should let user configure some default attributes for tags created: - User should be able to define what the default point security should be - User should be able to decide if tags should be created as Poll or Advise
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Add a Trace Route feature to PI Ping interface

Add ping -i feature to the interface and allow for either the output of the ping time or destination in the PI tag. Case: This will allow for IT to monitor the network path taken in communication from one site to another. If the route has change...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Visual indication of EventFrame time range to Trends

Possibility of adding event frame to PI Vision trend to highlight time frame of the event. Could change the background color for example. Would help visualize impact of some events on process values. (see attach image example)
Emmanuelle almost 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

‘Star Trek Medical Dashboard’ style Gauge

a ‘Star Trek medical dashboard’ style moving analogue gauge would align with the recommendations within “ ANSI/ISA-101.01-2015 Human Machine Interfaces for Process Automation Systems, ISBN 978-1-941546-46-8 “, which gives guidelines on the creatio...
Guest almost 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server. There are documented known issues related to the slow ICU loading...
Guest 12 months ago in PI Interfaces / Other Interfaces 0 No status