Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add Logarithmic scale for all symbols

you should add log scales for all symbols..
Guest almost 4 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Extend the history recovery max period for PI Cloud Connect to longer than 30 days

Allow history recovery for PI Cloud Connect to be longer than the current max of 30 days
Guest almost 4 years ago in PI Cloud Connect 1 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 11 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee almost 3 years ago in AVEVA™ Adapters / General 2 No status

Bring back column filters in event frame tables!

the column filters in event frame tables were great! with the addition of other attributes in tables, I was really looking forward to having column filters on these as well. this allows for much greater slicing of event frames and much better perf...
rfesler almost 4 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Improve Attribute Filter Logic in Asset Comparison Table to Distinguish Between Digital States and Numeric Values

In PI Vision, when using dynamic search criteria in an Asset Comparison Table, attribute filters such as "Drive_G >= 15" can produce misleading results because PI Vision does not differentiate between digital states and actual numeric values. D...
Guest about 1 year ago in AVEVA™ PI Vision™ / Symbols 0 No status

Ability to control PI Vision time series symbols timerange based on attribute value

Possibility to control PI Vision time series symbols (trend/table) values based on attribute value formula for its time range duration.
Eduardo Miller 5 months ago in AVEVA™ PI Vision™ / Symbols 0 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status