To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Min/Max Timestamps

Need Timestamps for Minimum and Maximum values in Table
Rebekah@SCG about 4 years ago in AVEVA™ PI Vision™ / Symbols 2 Declined

Vertical trends in PI Vision

Vertical trends in PI Vision
Guest about 4 years ago in AVEVA™ PI Vision™ / Symbols 1 Declined

Custom time ranges in custom symbols

Set the new functionality introduced in PI Vision 2020 (Custom Time range) available for custom symbols too, as right now is is built into the native Trend symbol for PI Vision 2020 only
Guest about 4 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

processor rate(s) for Processor properties of Modbus Adapter Service Health

Visualize and understand usage when trended with other diagnostic properties.
Guest 3 months ago in AVEVA™ Adapters / General 1 No status

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Guest 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Allow Adaptors to run in Docker

Allow Adaptors to run in Docker. This would ease the roll-out and management of adaptors. Also new Cisco switches now allow Docker instances on the switch, limiting the need for extra hardware.
Erik Prins over 2 years ago in AVEVA™ Adapters / General 2 Already exists

Allow setting interpolation type in Adapters

We would like to be able to specify the interpolation type (linear vs step) when Adapter creates tags in Archive.
Damon Vinciguerra about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Show transparent shapes in design mode

When modifying a display you cannot see where transparent shapes are. If they could be made visible when in design mode it would be far easier to maintain displays.
Mike Horrocks over 1 year ago in AVEVA™ PI Vision™ / Symbols 0 No status

Allow option to prevent trend interpolation after the most recent data value

Currently, trends interpolate a line after the most recent data value--which means that if the last value occurred two hours ago a flat line will be drawn on the trend from the last value until now, which can erroneously give the impression that d...
Guest about 4 years ago in AVEVA™ PI Vision™ / Symbols 2 Declined