Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Configure regression line format on XY Plot

As a display author, I would like to configure the format of a regression like (e.g color and line weight) so that the regression line stands out from the points on an XY Plot.
Guest almost 4 years ago in AVEVA™ PI Vision™ / Symbols 1 Declined

Easier multistating of grouped symbols

As a PI Vision display creator, I would like to be able to easily multistate objects after I have grouped them together. This way all of the objects can have the same conditions for multistating (e.g. multiple adjacent sections of piping in a proc...
Guest almost 4 years ago in AVEVA™ PI Vision™ / Symbols 0 Declined

Support OPC UA ReverseConnect

Support ReverseConnect, allowing for the connection to be establish from the more secure area where the OPC Server reside to the least secure area where the OPC Client / Adapter resides. This is implemented in many other client tools and SDK such...
Gabriel Verreault almost 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest almost 4 years ago in AVEVA™ Adapters / General 0 Tell us more

Support an analogue to the "step" PI Point attribute when creating PI Points

Even though it will indeed be useful to be able to specify whether data should be retrieved in a step-wise fashion, for new PI Points (assuming you're writing data to a PI Connector), it's important to be able to specify that those tags should hav...
Guest almost 4 years ago in Developer Resources / Open Message Format (OMF) 1 In development

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 8 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

XY Plots with Multiple Y scales enabled should allow custom limits for each scale

When creating a XY Plot with more than one attribute added to the Y Axis and enabling 'Scales'->'Multiple Y Scales', the user should have the possibility to select the voice 'Custom Limits'. This option is currently available only if the checkb...
Guest over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Adapter for RDBMS to support multiple rows with same "Timestamp" colum as IndexColumn

As of version 1.x, with the IndexColumn being specified in the dataselection, the Adapter will require that each row in the source Database to have its own unique timestamp. If there are multiple rows with the same timestamp, first value with the ...
Ee Sheing Lee about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 4 Tell us more

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 8 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 2 No status

Expand options under the Label (or Legend Label for trends) dropdown to include Instrument Tag.

It would be helpful to add more options under the Label (or Legend Label for trends) dropdown to include InstrumentTag and other tag attributes. Currently, the options for tags are name, description, or custom (free text) It would be great to incl...
Bryan Klosiewicz about 1 year ago in AVEVA™ PI Vision™ / Symbols 0 No status