Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 396 of 5213

GUI Front End for UA Adapter

The OPC UA Adapter is a replacement for the OPC UA Connector and should thus provide similar functionality by providing a GUI.
Jonathan Brutt over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 7 Planned

Trend: Ability to multistate trace pen color

As a PI Vision user, I want to be able to configure a trend's trace color to be conditional based on the trace value. Each section of the trace should be colored appropriately based on its value at that time. See attached image for example.
Ryan McErlean over 3 years ago in AVEVA™ PI Vision™ / Symbols 5 No status

Bitmask Functionality in AVEVA PI OPC UA Adapter

During the migration from the PI OPC DA Interface to the AVEVA PI OPC UA Adapter, we noticed that the ability to apply bitmasks to incoming values is no longer supported. This functionality is critical in many existing implementations, especially ...
Dennis Fendel 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 Future consideration

Include buffering metrics in adapter health

In the OmfEgress component in adapter health the metrics are limited to DeviceStatus, and IO rate. Another key metric for this component is the buffering state. To keep it simple it would be useful to have the number of events in the buffer. This ...
Mike Horrocks 9 months ago in AVEVA™ Adapters / General 0 No status

Support for the Galileosky Protocol

Need an option for direct integration of Galileosky GPS tracking devices with the AVEVA PI System without third-party middleware. The devices primarily use the proprietary Galileosky binary protocol (TCP-based, port 20332 by default) for real-time...
Mohammed Qasim Asghar 21 days ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

XY Plot: Asset / Event Comparison

Be able to compare multiple assets against each other using an XY plot. User Story: As a process engineer, Lalit wants to compare data from multiple assets against each other on the same XY Plot SO THAT he can compare the performance of each asse...
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 3 No status

View Annotations via PI Vision

Ability to see annotations, such as those from Manual Logger, in Pi Vision.
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 4 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Trend: Scale grouping

On the trend symbol, we would like to select specific tags to share a single scale which auto-updates, while the other tags use independent scales. All on the same trend. For example on the same trend, • PICXXXXXX.PV & PICXXXXXX.SV need to sh...
Ananya Bhakat over 3 years ago in AVEVA™ PI Vision™ / Symbols 15 Planned