To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 403 of 5259

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide additional time formatting options for RDBMS Queries

Background: Today we are collecting data from our AspenTech IP21 Server thorugh the PI Adapter for OPC UA and the related AspenTech OPC UA Server. This works perfectly fine for analogue data but not for data which is providing us equipment status ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for RDBMS 1 Tell us more

Allow to adjust the content of the tooltip on trend symbol

When you choose to display the tag description, the tag name is displayed in the tooltip. But when you choose to display the description, the tag name is also displayed in the tooltip : in that case Pi Vision displays the same information twice. I...
jerome.boudon over 2 years ago in AVEVA™ PI Vision™ / Symbols 1 No status

Ability to customize the icon of the Target Indicator (default is a triangle)

Given the existing target indicator feature in PI Vision: It is currently limited to only use a triangle graphic/icon/shape. It would be nice to be cable to choose various shapes/graphics for the indicator, or even be able to use a custom graphic ...
Guest over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Time Based gant chart for Enum Set attributes or Digital State Tags / Multistates New SYmbol

This symbol would be a strip that would would change color depending on the state of a digital state tag or enum set attribute as a multistate..
Martin Bryant over 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Better support of IP21 OPC UA Server with PI Adapter for OPC UA

We have been using the PI Adapter for OPC UA in its current version to collect data from IP21 OPC UA Server during a lighthouse project. However, the configuration was a bit cumbersome since the OPC UA Server of AspenTech uses an opaque mechanism ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Have the ability to show logged user information on the PI Vision display

It would be nice to be able to show the logged on user directly on the display.
Jessica Rammo almost 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Make a BACnet/SC adapter

BACnet/SC is essentially the same as BACnet/IP... but secures the communication
Nate Anderson almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 1 No status

Radial Gauge- Use PI Tags for Ranges

Instead of hard coding the color ranges on a dial allow us to use PI tags. This way I can make a radial gauge grade dependent with different grades have there own color ranges for target, high, low, etc..
mjwakema almost 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Allow multiple references to holding register for bit extraction

Given a 16bit integer holding register, in certain instances we only care for specific bits rather the integer value. Using the bitmap allows the selection of those specific bits but you can only reference the register once. i.e. In data selection...
Matthew Kishe about 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 8 Future consideration