Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 789 of 5274

Show URL string values in Table

Currently PI Vision Table shows a link icon when it has detected String data items that stores a URL data value: https://docs.aveva.com/bundle/pi-vision/page/1009839.html Without seeing the URL there is no visual indication of a change to the URL ...
David Wang about 2 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Separated output folder for different data source

I am interested to be able to configure for each data source separately output folder where processed data files are stored. Currently, all processed data files are moved to one OUTPUT folder and afterwards zipped. I would like to have this functi...
Guest about 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha about 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

About PI Vision Bar Graph Symbols

If you assign a PI Point with a value that exceeds the upper and lower limits with a bar graph symbol, an arrow mark will be displayed, but I would like a function to turn this on and off.
Guest about 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Filters in Collections & Asset tables for attributes...

Collections and Asset tables allow you to select the rows in the tables and the items in the collections by element categories and to establish a root and search down the tree. If you were to allow these tools to also select attributes by category...
Martin Bryant about 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Multistate: Make Images visible/invisible based on data item value.

it would be great if we could also hide/show images based on their value. For now this is only possible with shapes/symbols and text.
Guest about 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status

Support of EEC (Elliptic Curve Digital Signature Algorithm ) Certificates

Make the Connector, DCM and Relay support EEC (Elliptic Curve Digital Signature Algorithm) Certificates in future versions. Admin Certificates can be exchanged manually usinmg netsh, but the usage of RSA encrypted certificates is required here.
Julian Baur about 3 years ago in PI Connectors / General 0 No status

PI System Connector should be able to Parameterize AF objects (like attributes) to dynamically update between environments

In Asset Framework, we are able to use substitution parameters to define PI Point Data References because the variable is able to resolve based on the template. PI System Connector is used to synchronize, and keep perfect copies of the assets betw...
zachary cmelak about 1 year ago in PI Connectors / PI System Connector 0 No status

PI System Connector: Allow subset of event frames to be replicated

Currently you only have the ability to replicate ALL event frames and only if you want to replicate the entire AF database. We have one main AF database with many different types of event frames; however we do not want to replicate them all. It wo...
Rebekah_Wilson about 2 years ago in PI Connectors / PI System Connector 1 No status

PI Vision trend sampled data

Ability to set PI Vision trend/time range symbols sampling frequency.
Eduardo Miller over 3 years ago in AVEVA™ PI Vision™ / Symbols 0 No status