To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Audit trail logs activation and de-activation

One of my customers requirements change regarding Audit Trail: it's required that If an Audit trail can be turned off by anyone, then it should be detectable. Right now, turning off an Audit trail requires a system restart which is highly detectab...
Erik Prins 4 months ago in AVEVA™ PI Server / General 1 No status
114 VOTE

"Outputs at Start"group

It would be nice if there were an "Output at start" option to output values at the start of an event frame. Currently there is an "Outputs at close" option for Event Frames.
Guest almost 4 years ago in AVEVA™ PI Server / Event Frames (EF) 40 No status
113 VOTE

List all Notifications and its subscribers

Managing thousands of notifications can be difficult. There should be an option to export all the notifications and its subscribers. In PI Builder, you can find information about notifications via Contacts and Elements. There should be a direct wa...
Guest almost 4 years ago in AVEVA™ PI Server / Notifications 10 No status
109 VOTE

Easily deploying and maintaining AF objects in multiple remote AF databases

Originally posted on PI Square at https://pisquare.osisoft.com/ideas/5538-easily-deploying-and-maintaining-af-objects-in-multiple-remote-af-databases Today, one of the method that can be used to selectively reconcile object changes (including tem...
Guest almost 4 years ago in AVEVA™ PI Server / Asset Framework (AF) 14 No status
106 VOTE

Support Analysis Data Reference Step Functionality

Use case: User wants to trend Analysis Data Reference in client tools (Processbook, Coresight). User doesn’t want to create a PI tag for this output. Currently, the AnalysisDR ignores step, even if it’s input attributes are step.
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 9 No status
104 VOTE

Be able to disable auto backfilling on a per analysis basis

Currently in the analysis service configuration there is a parameter called “AutoBackfillingEnabled” which affects the analysis calculations in a global basis. It would be great if it were possible to disable the auto backfilling to individual cal...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 8 No status
104 VOTE

Analytics function for Last Good Value

We have come across a number of occasions where we want to bring in the last good value of an attribute as an input to an analytics.  But there is no way to do this without additional attributes and analytics.  It would be convenient if ...
taterhead247 almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 10 Tell us more
103 VOTE

The old PI roadmap allowed us to perform some software release planning. Can you bring something like that in?

The old Roadmap had planning lists, such that we had some clue to product updates and we could plan our internal software release schedules. The new roadmap is a great glossy for general long term strategies, but doesn't help us know what software...
jdjohnstn almost 4 years ago in AVEVA™ PI Server / General 12 No status
101 VOTE

Support different data retention policies

As an administrator, I need to ability to configure the life span of my PI data, so that data are kept or deleted accordingly. For example, data that should be deleted based on corporate mandates and data that should be kept forever are handled ac...
Guest almost 4 years ago in AVEVA™ PI Server / Data Archive 5 No status

Be able to set or force time range to NOW or specific time for when opening displays

Displays should open with the time of "now" or have a way to default it to now or set time ranges. If someone saves a display that is scrolled back in time the display opens in that time range. A person that opens a display and does not see it is ...