To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 85 of 5194

Enable the option to not sync/overwrite pi point attributes for PI Connector GE e-terrahabitat after connector is started

As of version 1.1.1.42, by specifing tag under a given field node, this allows you to set any PI point attribute you want with an associated value. Furthermore, you can specify an associated key filter for that attribute. However, if we manually ...
Ee Sheing Lee over 3 years ago in PI Connectors / Other specific PI Connector 3 Declined

Allow PI Server components to be removed at installation time

Currently, when you run the PI Server install kit to perform an upgrade, existing PI Server components cannot be unselected, and so they are upgraded. This gives the impression that they cannot be uninstalled, but they can actually be uninstalled ...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Installation 0 Declined

Allow NTLM-authenticated local accounts while installing PI Analysis Service on a computer other than the PI Asset Framework computer

After installation, the PI Analysis Service can run under a local account even if the PI Asset Framework is installed on a different computer, since NTLM authentication can be used between both computers. However, the PI Server install kit does no...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Installation 0 No status

Allow user to select if Services start after upgrade

Give the user the option to not start the PI Services following an upgrade. This allows the user further control, especially during an outage/downtime event to perform the first reboot after an upgrade without beginning to take on data or connecti...
Nathan Skitt over 3 years ago in AVEVA™ PI Server / Installation 0 No status

PI Connector for Siemens SIMATIC PCS7 relay support

Allows customers to leverage the PI Connector relay for improved security, ease of deployment and maintenance when PI Connector for Siemens SIMATIC PCS7 is implemented in a process network with DMZ communication to the corporate network.
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Build native connectivity to Roche Diagnostics QC systems

Roche Diagnostics has built a suit of quality control devices (CEDEX Analyzers) for process control in bio-processing. It would be very important for the business to create in collaboration with Roche Diagnostics a native PI Connector.
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Add support for the Kongsberg WITSML server to the PI Connector for WITSML

No description provided
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

IEC 60870-5-104: Interrogation Type

Currently, the Interrogation Type selection options are: - General interrogation - General and groups interrogation - General, groups and counters interrogation There should be an option for General and counters interrogation
Gabriel Verreault over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Allow filtering of source points

In the HabConnect Connector the only filtering of source composite ID's for inclusion into PI is through use of wildcards. As a user I want to filter not at the query level to sampler, rather filter out tags in the result set (preferably using reg...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

PI Connector for IEC 61850 is unable to retrieve more than 100 top-level objects in the hierarchy

Currently, PI Connector for IEC 61850 will only retrieve the first 100 top-level ("vmdSpecific") items in the source object hierarchy during its initial request. If any reports exist in items beyond the first 100 top-level objects, then the Connec...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status