Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 191 of 5219

Provide an audit function

The idea would be to provide a feature which alllows a PI System Admin to get a report of all the rights that are granted to a user or a group of user for all the PI system product which have a link with security
jerome.boudon over 3 years ago in AVEVA™ PI Server / Security 0 Declined

Securing the PI System

As an ICS systems engineer, I need to understand and easily configure Authentication and Authorization settings to secure the PI System from the point of data collection to data access and remote display viewing.
Guest over 3 years ago in AVEVA™ PI Server / Security 0 Declined

Allow security to be set at AFAttribute level

I want to give access to only some attributes on some elements to some users. Currently, the smallest granularity in AF Security is at the element, not attribute level. Sure there are some workarounds like creating derived templates, but it would ...
Guest over 3 years ago in AVEVA™ PI Server / Security 0 Declined

Remotely view logs

I understand that you can remotely view logs using pigetmsg. However this solution does not work for me as the interface is on a controlled network that only allows outbound traffic. I would like a way for the interface node to be able to push out...
Guest over 3 years ago in PI Interfaces / General 1 No status

Improved handling of PI Write failures

Provide a configuration option in UniInt interfaces, to enable shutdown of the interface if it consistently receives error messages when attempting to write to PI. Recently had an interface successfully connect to PI but not achieve write access t...
Guest over 3 years ago in PI Interfaces / General 0 No status

Allow scan class 0 to be monitored via Performance Counters

As a PI System Administrator, I would like to monitor the point count and other parameters for scan class 0 via Performance Counters. Currently, this is only exposed via the UniInt Health Tags.
Guest over 3 years ago in PI Interfaces / General 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status