To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 191 of 5219

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

View PI Adapter log files via REST calls

We would like to be able to see the adapter log files via REST calls. Going to the machine itself to view is problematic because of remoting into the router and then going into the container to view. I think in a lot of containerized situations a ...
Allison Muraski over 3 years ago in AVEVA™ Adapters / General 3 Tell us more

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Move Auditviewer function away from local PI System access

I want to run the Auditviewer function as a unprivileged remote user, moving away from the current requirement to run as a local user on the PI Data Archive Server.  This is so I can minimize security risk associated with local user access on...
Guest over 3 years ago in AVEVA™ PI Server / Security 1 Declined

Provide a central point to manage the security for the whole PI System

Instead of having several admlin tools to manage the security for data archive, AF, PI Vision, PI Integrators Could you provide a centralized security management interface which could manage all the existing and upcoming OSIsoft tools
jerome.boudon over 3 years ago in AVEVA™ PI Server / Security 1 No status

Add an option to receive real-time data in client during buffer recovery

Add an option to receive real-time data in the client during recovery of buffered data: The default behaviour of our interfaces / buffering is that after a connection failure the buffer will be flushed and data will be sent in it’s original order...
Guest over 3 years ago in PI Interfaces / General 5 No status

Customize UniInt Failover Sync File Permissions

Prior to UniInt v4.6.0.60, UFO sync files created during interface startup would inherit file permissions from their parent folder (assuming child inheritance had been enabled on the folder). With UniInt v4.6.0.60, this behavior changed and now s...
Guest over 3 years ago in PI Interfaces / General 1 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

PI Adapter for Structured Data Files support for files with format: tag,timestamp,value

input file format is (where identifier is the tag/stream name): identifier, timestamp,value identifier, timestamp,value ...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files / General 1 Tell us more