Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 46 of 5219

Mass create data source list for PI Connector

For the PI Connector for EtherNet IP you can have up to 100 data sources. Typing in all of them is tedious. It would be nice if we could copy/paste information from Excel OR have a structured import/export file to the data source list.
Dan.Louchbaum over 3 years ago in PI Connectors / PI Connector for Ethernet/IP 1 No status

PI Connector for Ethernet IP should retrieve tagnames from the PLC array

The AF Hierarchy that is created by the connector does not take into consideration any of the tagnames within the PLC array, it just creates attributes for them as slot.n where “n” is a number corresponding to the array position. Not only is this ...
Allison Muraski over 3 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

We need a method to send pi message log to syslog server

Provide a configurable export of PI Message log to syslog server.
Guest over 3 years ago in AVEVA™ PI Server / Security 0 No status

Auditviewer separation of roles

I want to separate the security roles between 1) the ability to run an Auditviewer report and (potentially) associate a change control record to a configuration change and 2) the PI Admin Role in order to minimize security risk.
Guest over 3 years ago in AVEVA™ PI Server / Security 1 No status

Be able to configure PI AF security in a single PI System Explorer window

Currently, there are 2 windows to configure PI AF security, and it is a pain to switch between them: File → Database → Edit Security, which is used to assign permissions to identities File → Server Properties → Identities tab and Mappings tab, whi...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 1 Declined

Support string data types for PI Connector for EtherNet/IP

String data, such as serial numbers, are supported by the EtherNet/IP protocol and are often collected to help understand what was being made by a piece of equipment at any given time.
Guest over 3 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Connector provides Timestamps

The EtherNet/IP protocol does not specify timestamps when data is transmitted, the connector currently assigns the timestamps base on when the data is being processed. This leads to the following issue, if the network/computer/etc gets busy, we w...
Allison Muraski over 3 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Have an option in AF Security to not pass down database security to newly created objects

Use case: We want to give a user read access to a single element. All future elements created inherit the Database level Security, meaning the user will also have read access to all future created elements.
Guest over 3 years ago in AVEVA™ PI Server / Security 0 Declined

Hide Certain PI Point Attributes from Users

Implement a way to hide the contents of a PI point attribute, specifically the Instrumenttag attribute. With many PI interfaces, the InstrumentTag attribute will store the IP address of the source, and we (as well as many other utilities) have a r...
Guest over 3 years ago in AVEVA™ PI Server / Security 1 Declined

User rights for viewing analytics

In many cases analytics should not be visible to everyone having right to view an AF-Database. Should be possible to direct whom should have view access to analytics. This is an extension to the obivious right to change analytics :)
Guest over 3 years ago in AVEVA™ PI Server / Security 2 No status