To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 47 of 5199

Allow Federation of ClientIDs and tokens from Entra ID into AVEVA Identity Manager

For clients who previously relied on claims authentication with PI Web API, it would be useful to be able to reproduce a similar authentication flow with bearer authentication and the AVEVA Identity Manager in PI Server 2023. Currently, federation...
Housnat Aboubacar about 1 year ago in AVEVA™ PI Server / Security 1 No status

Ability to manage non-impersonated linked tables without PI AF Server Admin privilegies

PI AF Admin would like grant permissions for users that are not level server admins to create and edit non-impersonated linked tables. Currently this only allowed for AF server admins or using impersonated linked tables. User guide: https://liv...
Guest over 3 years ago in AVEVA™ PI Server / Security 3 No status

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Tombayu Hidayat about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

We need a method to send pi message log to syslog server

Provide a configurable export of PI Message log to syslog server.
Guest over 3 years ago in AVEVA™ PI Server / Security 0 No status

Allow MQTT adapter to parse timestamps in local time without specifying a timezone suffix to each timestamp

We would like the MQTT Adapter to be able to interpret timestamps in local time without needing to explicitly state the timezone or UTC offset in each timestamp, but for the adapter to always interpret the timestamps as being in a specific timezon...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Auditviewer separation of roles

I want to separate the security roles between 1) the ability to run an Auditviewer report and (potentially) associate a change control record to a configuration change and 2) the PI Admin Role in order to minimize security risk.
Guest over 3 years ago in AVEVA™ PI Server / Security 1 No status

Be able to configure PI AF security in a single PI System Explorer window

Currently, there are 2 windows to configure PI AF security, and it is a pain to switch between them: File → Database → Edit Security, which is used to assign permissions to identities File → Server Properties → Identities tab and Mappings tab, whi...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 1 Declined

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Allow PI Adapter for MQTT to log the raw json payload received from the broker

For troubleshooting, it can be very helpful to see the raw json payload that the adapter has received from the broker, rather than just the error response from the attempted parsing. It can be difficult to know why a parsing attempt has failed wit...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 2 Future consideration

Have an option in AF Security to not pass down database security to newly created objects

Use case: We want to give a user read access to a single element. All future elements created inherit the Database level Security, meaning the user will also have read access to all future created elements.