To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 644 of 5275

Tuning parameters or PI setting that could be enabled to prevent duplicate data

Tuning parameters or PI setting that could be enabled to prevent duplicate data(tag, timestamp, value the same) from being inserted into PI.  Would be a global setting that could be applied at the archive level to prevent all interface types ...
Guest over 3 years ago in AVEVA™ PI Server / System Management 2 Declined

See latest use (Date/Time) of a configured trust (or MDB Interfaces entry) within PI SMT

Every time a PI Database is restarted the interfaces and connections will reestablish their connection to the PI Database fresh restarted PI Database. This is an opportunity to write the last used (last seen) time stamp for the configured PI Trust...
Guest over 3 years ago in AVEVA™ PI Server / System Management 1 Declined

By default, do not install the PI Module Database Builder when the PI System Management Tools install kit is run

Similar to how the PI DataLink install kit included PI DataLink (Legacy) but required manual modification to setup.ini in order to install it (this was before PI DataLink Legacy was dropped from the PI DataLink install kit entirely), the PI Module...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / System Management 1 No status

Expose "Tuning Parameters" in AFSDK

It would be very intesting to access tuning parameters (that are present in PI SMT) via AFSDK. This is interesting when you have to manage dozens of PI DA servers and you want to ensure they are all correctly configured (and no change are performe...
Gael over 3 years ago in AVEVA™ PI Server / System Management 1 No status

PI to CONNECT Installation Footprint

As a PI System Administrator, I would like a way to deploy PI to CONNECT in a secure and manageable way so that it is easy to maintain, and I can trust it is secure. Currently, AVEVA recommends PI to CONNECT be installed on a separate computer fro...
Guest over 3 years ago in PI to CONNECT 0 No status

Sync PI to CONNECT Value Property UoMs with the source tag's EngUnits

By placing the engineering units from the data archive into a stream metadata, it precludes their usage within CONNECT's UoM functionality (such as data view column labels for example). The EngUnits won't be trivial to sync into CONNECT, but an at...
Guest over 3 years ago in PI to CONNECT 1 No status

Add a type casting function or operator

The INI files would be shorter and more readable if the PI Connector for UFL had a type casting function or operator. For example, if you are incrementing a Counter variable (type Int32) for each data line, and your tag names are Tag1, Tag2, etc....
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Make a version of SkipFile() that stops processing the current file immediately

The current SkipFile() function tells the PI Connector for UFL to skip the remaining lines in the file, but the PI Connector for UFL will continue to execute the rest of the code in the "per message" section that the current line triggered. Pleas...
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

UFL Connector - sort input files by parameters other than name

Allow the UFL Connector to sort input files by parameters other than the name.  This will be useful in cases where file naming conventions will lead to large amounts of OOO data.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

Uninstall only the installed files & folders

It is standard for uninstallations to follow a procedure similar to this: Remove all files that were added during the installation. Then remove all folders that were added during the installation if they are currently empty. The PI Connector for ...
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 1 No status