To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 89 of 5194

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface not truncate the trailing "-#" index (e.g. UnitProcedureName-1) at the end of a Unit Procedure

Some FactoryTalk batch processes have overlapping Unit Procedures with trailing indexes. Because the trailing index is truncated it results in overlapping Unit Procedures with the same name which are then merged. The desired behavior would be for ...
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface capture "Active Step Change Commencing" events as event frames

Some FactoryTalk batch processes require "Active Step Change Commencing" event to be part of the batch hierarchy however the PI Interface for Factory Talk Batch starts event frames only on [EVENT] = "System Message" or "State Change".
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Distinguish between types of OLE objects during the migration analysis

Currently if a .PDI file contains an OLE object, which could be something as simple as an image embedded in the file using Insert > Object in ProcessBook, the OLE object can't be migrated. The Analysis Results return a warning that the "File co...
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

Vision migration of Processbook custom trend axis

Support Custom axis settings. to avoid this current issue "Unsupported legend option;Custom axis settings are not supported;Scales with different max and min types are not supported.;Trends with different trace scale ranges are not supported unde...
Matt Voll over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 1 No status

Capture data from ABB 800xA that doesn't follow ISA88

ABB 800xA offers a batch capture mode that is more flexible than ISA88 since it doesn't match all unit procedures to units, but rather acquires them at the beginning of the batch. Currently the interface is designed to only retrieve batches that f...
Alan Izar over 3 years ago in PI Interfaces / Batch Interfaces 3 Declined

Batch Interface for Honeywell Experion

We are in need of a PI Batch/AF Events Interface to store data from Honeywell Experion Batch or Honeywell Procedure Analyst into PI Asset Framework.
Jürgen Schmidt over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

Add feature for PB to PI Vision Migration Utility to use local folder if target linked display cannot be resolved.

As PI Vision admin I have to migrate ProcessBook displays from several users throughout the company. There is no easy way to open each display and check if the target display path is valid and fix via PI Processbook Support Tool before running the...
Alex Santos over 2 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

PB to Vision Display Migration Utility: Add support for UNC style file paths

Some organizations are discontinuing the use of mapped drive letters since they are a known cyber attack vector and are instead using UNC file paths (eg. \\fileserver\share) to access network shares. There is no way to navigate to a network locat...
Guest over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

Better migration of symbol library symbols using the PI ProcessBook to PI Vision Migration Utility

The color of some symbol library symbols is different in PI ProcessBook and PI Vision after migrating PI ProcessBook displays to PI Vision. It would be nice if the color did not change, or if the Migration Utility allowed users to choose the desti...
Jaedyn Larson over 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status