Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 106 of 5194

Limit rate of published changes through PI Builder

A lot of PI servers we work with have a high system load. When we create, change or delete PI Points in PI Builder we have to do a few hundred points at a time and monitor the Pending Events counter from Update Subsystem on the PI server to make s...
Robert almost 2 years ago in AVEVA™ PI Server / PI Builder 0 No status

Batch interface to AF connection health monitoring tag

Having a health tag for batch interfaces which monitors the connection status between the interface and its corresponding AF server. This way, users can be informed if there are any issues with the interface creating event frames on AF.
Guest about 2 years ago in PI Interfaces / Batch Interfaces 0 No status

Use default servers and AF database from local KST for first time PI Builder users

As a user, I want my experience to be as seamless as possible when using PI Builder so that I can get the information I need quicker. Currently, PI Builder will Default the servers/database chosen to when a user first opens up PI Builder (after a...
Guest over 3 years ago in AVEVA™ PI Server / PI Builder 0 No status

More flexible search results for PI Builder

Allow users more selection of which columns to include in search results (before tag selection). Some customers may wish to reference tag metadata that cannot currently be displayed, including InstrumentTag and UserInt1. Note that this is not ref...
Guest over 3 years ago in AVEVA™ PI Server / PI Builder 2 No status

PI BES Interface (i.e. PI EMDVB): aliasing of Unit Names

Currently the interface creates PI UnitBatches or Event Frames associated to Units (PI Units or AF Elements) determined by some placeholders specified at the "Unit Procedure" level; the default is "[AREA]\[PROCESSCELL]\[UNIT]". Moreover the inter...
MAl over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

Ability to setup scheduled history recovery in PI Event Frame Generator Interface

No description provided
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI EFGEN Interface -- Allow the "time true" fuction for EFGen

in order to eliminate unwanted or noise event which be triggered and recovered in a short period.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

EFGEN - Allow Active Point Trigger Based on Specific Value/Logic/Calculation

Using EFGen, currently an EF can only be triggered based on the zeroth state of the Active Point. This makes is impossible to trigger different events based on specific values of a single PI Tag. I am trying to implement a batch structure using ...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

EMERSON PK based DCS - EMDVB Interface support

Emerson has a new PK Controller based DCS available (in lieu of full blown DeltaV). This new device is contained with OPC-UA and Batch Exec/Historian. We want support for the existing EMDVB interface to supply S88 based batches into PI Event Frame...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

Add support for workgroups for PI Interface for Emerson DeltaV Syncade

Add support for workgroups for PI Interface for Emerson DeltaV Syncade
Alan Izar over 3 years ago in PI Interfaces / Batch Interfaces 2 Declined