Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 189 of 5194

PI EMDVB Interface - Rename Parsed Files

PI EMDVB Interface - Rename Parsed Files.  Files that get renamed to .999 is no longer available with PI EMDVB.  This file renaming feature was very useful from a system maintenance perspective.  We would easily remove .999 from the...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI EFGen 4.1+ has limited recovery capabilities

Up to PI EFGen 4.0, we were able to backfill OOO Event Frames by simply inputting the start and end time of the corresponding period. Since 4.1, this must be done in a per-event basis, since larger time ranges are modified so that RST matches the ...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 No status

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface not truncate the trailing "-#" index (e.g. UnitProcedureName-1) at the end of a Unit Procedure

Some FactoryTalk batch processes have overlapping Unit Procedures with trailing indexes. Because the trailing index is truncated it results in overlapping Unit Procedures with the same name which are then merged. The desired behavior would be for ...
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface capture "Active Step Change Commencing" events as event frames

Some FactoryTalk batch processes require "Active Step Change Commencing" event to be part of the batch hierarchy however the PI Interface for Factory Talk Batch starts event frames only on [EVENT] = "System Message" or "State Change".
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

PI Notifications automated emails need to display all receivers of the automated emails from the PI Notifications application, not just the singular user (me in this case).

PI Notifications automated emails need to display all receivers of the automated emails in the list of emails that the automated email was sent to. It is very important for the user (or receiver of the automated PI Notification email) to understan...
Phil Jones about 2 years ago in AVEVA™ PI Server / Notifications 1 No status

Share custom message formats between notification rule templates

Allow custom message formats to be shared between notification rule templates that live on the same element template and/or utilize the same event frame template. Example: An event frame template specifies an event frame attribute that will va...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 No status

Multiple AD Folders

At the moment it is only possible to select a single AD contact subfolder to link to contacts. We have our users spread over many subfolders based on location, organisation etc. It should be possible to specify multiple folders.
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 Declined

Notification Resend Count

It would be nice to have a Notification Resend Count that could be used as a content in notification formats.
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 No status

Notification acknowledge link

Currently, it is only possible to acknowledge a notification from PI Vision link, or directly from PI System Explorer. For users who are not currently using PI Vision, it will be impossible for them to acknowledge a notification directly from the ...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 Declined