Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1404 of 5193

PI BES Interface (i.e. PI EMDVB): aliasing of Unit Names

Currently the interface creates PI UnitBatches or Event Frames associated to Units (PI Units or AF Elements) determined by some placeholders specified at the "Unit Procedure" level; the default is "[AREA]\[PROCESSCELL]\[UNIT]". Moreover the inter...
MAl over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

Ability to setup scheduled history recovery in PI Event Frame Generator Interface

No description provided
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

PI EFGEN Interface -- Allow the "time true" fuction for EFGen

in order to eliminate unwanted or noise event which be triggered and recovered in a short period.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

EFGEN - Allow Active Point Trigger Based on Specific Value/Logic/Calculation

Using EFGen, currently an EF can only be triggered based on the zeroth state of the Active Point. This makes is impossible to trigger different events based on specific values of a single PI Tag. I am trying to implement a batch structure using ...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

EMERSON PK based DCS - EMDVB Interface support

Emerson has a new PK Controller based DCS available (in lieu of full blown DeltaV). This new device is contained with OPC-UA and Batch Exec/Historian. We want support for the existing EMDVB interface to supply S88 based batches into PI Event Frame...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 Declined

Add support for workgroups for PI Interface for Emerson DeltaV Syncade

Add support for workgroups for PI Interface for Emerson DeltaV Syncade
Alan Izar over 3 years ago in PI Interfaces / Batch Interfaces 2 Declined

Data Verification for the PI Interface for Emerson DeltaV Batch

Add a feature that performs a verification check of the data in PI against data in the DeltaV Historian and provide a report of any missing or mismatched data.
Guest over 3 years ago in PI Interfaces / Batch Interfaces 1 Declined

Supporting Decimal type for PI tag in PI Data Archive

For customers from special fields (eg: Pharma industry ), they would like the value to be accessed as exactly 16.168 , and would like to know if data type " Decimal " can be introduced for PI tags in PI Data Archive; Just like the following descri...
Peng Li about 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

Add Continue() Function To Asset Analytics

Similar to the Exit() function, a Continue() function would be very helpful in reducing the calculation load on my analysis service, in this case by not fully executing variables if a condition is true. For example, if I'm evaluating the state of ...
Kelsey Bobeck over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Remove Microsoft Visual Studio 2010 Tools For Office Runtime (VSTO Runtime) from any install kits that contain PI AF Client

According to this, VSTO Runtime is included with PI AF Client for the sake of PI Builder. The installation of VSTO Runtime also causes the 32-bit and 64-bit versions of the Visual C++ 2010 Redistributable to be installed as well. However, accordin...
Kenneth Barber over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 Declined